KS TA 2D User Manual Download Page 14

TA

 

2D

 

|2

 

CHANNEL

 

POWER

 

AMP

  

TA

 

2D

 

|OPERATING

 

INSTRUCTIONS

                                                                                                 

13

 

|

 

P a g e

 

CLEANING OF AMPLIFIER  

The fitted mesh filters (foam) for the cooling system should be regularly cleaned to maximize the 
air flow into the unit.  
 

TRANSPORTATION 

KS products are tools for daily professional use and are correspondingly robustly manufactured. 
You should, however, be aware of these aspects of note: 
 
As with all types of electronic devices, condensation and moisture must be avoided i.e. when the 
speaker comes from a cold and humid truck and is brought into a warm venue, give the system as 
much time as possible to heat up to venue temperature before powering on.  
 
Of course, direct exposure to liquids is never safe and should be prevented at all times. The 
vibrations of a transport vehicle are safe - all components and cabinetry are well assembled, 
secured with screwed or bolted parts for extra strength where necessary.  
 
It has however been shown that train or airplane transport without further packaging creates un-
due stress on KS products. We recommend for such situations shock resistant flight cases.  
 
Significant contamination by dust, etc. is dangerous for Electronic assemblies as it may cause a 
short circuit. It is therefore advisable, that the devices are periodically opened, and cleaned out 
with compressed air. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for TA 2D

Page 1: ...HE ULTIMATE SUBWOOFER TOOL USER MANUAL TA 2D 2 CHANNEL POWERAMP Thank you for purchasing a professional KS AUDIO product Please carefully follow the instructions in this manual to ensure long trouble...

Page 2: ...where they exit 11 Make sure the power cord remains readily accessible at all times 12 Only use attachments accessories specified by the manufacturer 13 Unplug device during lightning storms or when u...

Page 3: ...MER 8 POWER SUPPLY 8 COOLING 8 PROTECTION 8 DANTE OPTION 9 KS REMOTE CONTROL 9 DISPLAY 9 CONTROLS 9 CHANGING VALUES 9 MENU CONFIGURATION OVERVIEW 10 DIMENSIONS 11 SPECIFICATIONS 12 CLEANING OF AMPLIFI...

Page 4: ...at 4 ohms 2 channel amplifier with MOSFET technology This manual should help you to easily use this product Please read this manual carefully and do not hesitate contacting KS AUDIO headquarter or you...

Page 5: ...amplifier with MOSFET technology 1 standby switch with LED 2 mute switches channel 1 2 3 mute switch LED s 1 2 red mute 4 encoder knob 5 line direction knobs enter escape 6 ventilation grill screws 7...

Page 6: ...as well for recording studios or commercial industrial applications Please check when opening the packaging that there are no obvious damages due to transportation which could do harm to the product o...

Page 7: ...installations a transformer balanced output is preferable to avoid ground differentials and 50 Hz hum loops over mixed type cable runs The impedance is 2 x 10kOhm and is discreet independent for pin...

Page 8: ...cept analog sources as well Highest end 27 bit Sigma Delta converters in gain stacking along with a 64 times oversampling and a A rated signal to noise ratio of 110dB handle the conversion from analog...

Page 9: ...e low Please Note Be sure that the actual current draw for all speakers on the supply circuit does not exceed the maximum fuse rating on each amplifier After switching the amplifier on with the MAINS...

Page 10: ...perated via a rotary pulse transmitter with short stroke switches as well as 4 directional and 2 input keys The menu navigation in the display is intuitive and leads immediately to an applicable Resul...

Page 11: ...TA 2D 2 CHANNEL POWER AMP TA 2D OPERATING INSTRUCTIONS 10 P a g e MENU CONFIGURATION OVERVIEW...

Page 12: ...TA 2D 2 CHANNEL POWER AMP TA 2D OPERATING INSTRUCTIONS 11 P a g e DIMENSIONS...

Page 13: ...impedance min 2 ohms per channel power supply switch mode power supply with PFC mains voltage powercon input 100 250VAC amplification mode Class H MOSFET 3 rails supply input connectors 2x XLR3 in 2x...

Page 14: ...ive the system as much time as possible to heat up to venue temperature before powering on Of course direct exposure to liquids is never safe and should be prevented at all times The vibrations of a t...

Page 15: ...ght days 24 month limited warranty of manufacturer to the exclusion of all further claims and the following obligations Exchange or repair of defect devices whenever not subject of external damage van...

Page 16: ...to comply with the relevant fundamental safety and health criteria of the applicable EC respectively EU directives This declaration shall cease to be valid if alternations are made to the equipment w...

Page 17: ...r system carried e g from cold truck to warm and humid event location always allow equipment to acclimate for a while For rail cargo use professional shock absorbing flight cases To protect your equip...

Page 18: ...in the output stage of the equalizer a post oscillation of the impulse response On top of all this the mass of the driver creates an additional post oscillation initiated by the same impulse Combined...

Page 19: ...over points Instead of a phase shift as found in an analog cross over in the KS AUDIO digital process the time domain of the low pass signal is only considered and the rest of the process follows this...

Page 20: ...R AMP TA 2D OPERATING INSTRUCTIONS 19 P a g e NOTES CONTACT KS BESCHALLUNGSTECHNIK GMBH WESTENDSTRASSE 1 D 67310 HETTENLEIDELHEIM fon 49 6351 12744 0 fax 49 6351 12744 25 www ks audio de Model Serial...

Reviews: