![Krups XP7200 Series Servicing Manual Download Page 4](http://html1.mh-extra.com/html/krups/xp7200-series/xp7200-series_servicing-manual_2006090004.webp)
Coffee nozzle
Unclip the coffee pipe.
Remove the nozzle clip by means of a rule or a screwdriver placed between the clip and the
facing mount:
Clip
Technical mount: (provides access to the distributor and thermoblock/actuator sub-assembly)
Unclip and remove the coffee inlet pipe and disconnect the hose on the tamping head.
Remove the window.
Remove the mounting screws from the technical mount.
Disconnect the connectors and the electronic circuit wires and take the wires out of the grommets.
Remove the technical mount with the grinder in place (the wires connected to the actuator switches
pass through the shroud opening).
Thermoblock / NTC / soldered lugs sub-assembly
There is no provision for dismantling this sub-assembly.
The only parts which may be replaced are:
•
Tamping head parts (creamy seal, O-ring, coffee grid…)
•
The
ejection
scraper
•
The actuator switch control plate with its spring and 3 switches
•
The interface and its seal
•
The ejector rod "Barista" seal
Remove the 3 thermoblock/actuator sub-assembly mounting screws in the base.
Disconnect the distributor/thermoblock coffee hose from the distributor
Disconnect the thermoblock/distributor steam hose from the thermoblock system (if necessary
remove the drain from the distributor after disconnecting the coffee drain hose from the
distributor).
Disconnect the steam nozzle hose.
Thermoblock system and ejection scraper Interface
Remove the ejection scraper (this may be a little difficult as the screwdriver is not in line with
the screw).
Distributor
Remove the 2 distributor mounting screws in the base (Phillips-head indentation).
Disconnect the distributor/thermoblock steam hose from the thermoblock (remove the drain
from the distributor, if necessary after disconnecting the coffee drain hose from the distributor).
Remove the 3 thermoblock/actuator sub-assembly mounting screws in the base and tilt the
unit so as to have access to the hoses connected to the distributor.
Access to the distributor may be facilitated by removing the facing panel (2 4 clips)
and the facing mount (2 screws in the lower part).
Ejection rod "Barista" seal
Remove the tamping head
Unscrew the thermoblock/actuator from the bottom of the
coffee-maker and lift it up
Raise the ejector and remove the plunger head.
Remove the "Barista" seal.