If the customer is
demanding, change the
visu board.
Impossible to set the
date after
unplugging or cut-off
in current
Fault in the facing visu electronic
board
Validate the date when the
filter was first fitted.
Consequence: there will no
longer be any warning
message to replace the filter
Î
use the index on the top of
the filter to memorise the date
when the filter was first used
Visu boards concerned by
the bug: versions V6.8,
V6.9, V7.0 and V7.2
Display returns to
intial date when filter
fitted
Blue light 0/1
flashes rapidly
Drop in low voltage supply
through excessive
consumption
Check consumption of
distributor motor (distributor
opposing torque too high)
Risk of damage to the
electronic power board
AFTER-SALES (A-S) MODE OPERATION
1st-level A-S mode
This mode makes it possible to access information on the rate of use of different coffee-maker
functions.
Pictographic model
Access to A-S 1 via combination of the following keys:
S Strong Coffee key + Mains
Connection.
•
The Strong Coffee key enables functions to scroll and the Coffee key to return. No signalling.
•
Access counter values of the different functions via the Steam key and return via the same
Steam key. Signalling via the Calc light.
Function 1
1
Steam
Counter value
Calc
Steam
Strong coffee
Coffee
Function 2
2
Strong coffee
Coffee
Function N
N
Steam
Counter value
Calc
Steam
Steam
Counter value
Calc
Steam