Krups XP7200 Series Servicing Manual Download Page 11

 

PRE-LISTED FAULTS 

 
If the appliance is blocked because of a fault situation, identify the fault with the number displayed: 
 
Pictographic model display mode: 

  numbers from 1 to 9: fixed display 

  number > 9: display of a dash and successively all the numbers. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Picto 

no. 

Graph 

no. 

Function  

Nature 

Servicing 

1 1 

PosWaterDistrib 

The maximum time for the water distributor 
command has been reached without the tooth 
being detected 

Check operation of distributor 
switches 
Check distributor rotation (risk 
of drop in LV supply if distributor 
motor current too high). 
Check for wrong setting or 
position of motor in the 
distributor housing 

GroundCoffeeDistrib  The maximum time for the ground coffee 

distributor has been reached without the 
ground coffee proportioning switch being 
detected 

Concerns the ground coffee 
version 

3 3 

Cycle 

start 

conditions 

The distributor is in the original position 
but the actuator is not in the high  
po 
The actuator is in the low position and 
the actuator switch is still closed 

- Fault in the actuator high 
position switch (mechanical or 
electrical) 
- Distributor switch fault 
- Faulty electronic boards 
connection 
- Actuator switch short-circuited 

Pump in actuator 
down phase 

During the first seconds of pump start-up, 
volume is very low 

Pump unprimed (start of self-
priming cycle, fault 4 not 
displayed but recorded in 
memory of faults in line 6 of A-S 
mode) 
Distributor fault  
Actuator stuck in high position 

Æ

 not noted up to 5/10/05 

Dash 

1st number 

2nd number 

nth number 

 

11

Summary of Contents for XP7200 Series

Page 1: ...2 electronic boards for o thermoblock temperature regulation o mesuring the waterflow volume by counting flowmeter pulses o 1 cup 2 cup hot water graphic model steam cleaning and scale removal cycle...

Page 2: ...cing Facing mount mount Grinder Tamping head Control board if necessary replace board Power board Pump Flowmeter Thermoblock actuator Fuses Distributor Steam nozzle Coffee nozzle Body provides visual...

Page 3: ...by pressing on the top nut using a socket spanner or equivalent Disassemble the switch control plate Flowmeter No particular instructions Power electronic board Electronic circuit mount maintained in...

Page 4: ...onnect the distributor thermoblock coffee hose from the distributor Disconnect the thermoblock distributor steam hose from the thermoblock system if necessary remove the drain from the distributor aft...

Page 5: ...be replaced Use Norma Cobra 7 5 clamps Lock the clamps with gripping pliers and check that they have been properly assembled Grinder Indexing and mounting of the grinder ring on the coffee maker are t...

Page 6: ...embly line same as for V16 except that setting operation is carried out before the standard coffee cycle With cake tray draw and tank removed Press steam key mains connection o Blue On Off light comes...

Page 7: ...lay 1 2 3 4 5 Time for strong coffee grinding secs 6 7 8 9 10 grinder 2 15 02 2006 Lead Respect the earthwire routing The lead earthwire must not be in contact with moving parts stainless steel corner...

Page 8: ...When screwing be careful not to offset the tamping head mount Thermoblock and ejection scraper interface Take care when replacing the seal which must not protrude into the coffee chamber Distributor R...

Page 9: ...ghten counterclockwise Electronic boards Connectors on electronic boards check that connectors are well secured by the clips Check the coffee volume selector button for correct indexation 1 2 turn pos...

Page 10: ...see troubleshooting diagnosis table grinder not compliant quantity of ground coffee electronics setting not compliant with the grinder ejection ram stuck in high position cake tray replaced partially...

Page 11: ...maximum time for the ground coffee distributor has been reached without the ground coffee proportioning switch being detected Concerns the ground coffee version 3 3 Cycle start conditions The distrib...

Page 12: ...tank or with tank empty Water level board or bundle defective 8 8 Hot water and Coffee Pump After a certain time of pump control during coffee or water flow the circuit is considered to be blocked as...

Page 13: ...use which led to the coffee leaking Interface tank seal Thermoblock or water circuit scaled up Remove scale Replace scaled up item if scale removal ineffective Thermoblock coffee circuit clogged up by...

Page 14: ...circuit Volume of coffee in the cup does not comply Thermoblock or water circuit scaled up Remove scale Replace scaled up item if scale removal ineffective A few drops of water drip from the steam noz...

Page 15: ...ad and grinder spout Insert power board with drain time extended from 8 to 10 secs V21 picto and V14 graphic Bad thermoblock drain Leakage at tamping head seal level Check that the tamping head does n...

Page 16: ...consumption of distributor motor distributor opposing torque too high Risk of damage to the electronic power board AFTER SALES A S MODE OPERATION 1st level A S mode This mode makes it possible to acc...

Page 17: ...Times switched on number unit 13 Operating time min ON OFF light on 14 Rinsing number unit 15 Auto cut off duration 1 2 3 4 5 hours hour 16 Water hardness scale removal frequency level 0 1 2 3 4 valu...

Page 18: ...r No 13 Production date 14 First use date 15 Graphic software version Ref 16 Power software version Ref 17 Model grinder Model 18 Coffee function water volume ml 19 Steam function water volume ml 20 T...

Page 19: ...19...

Page 20: ...correct operation of switches for detecting the presence of draw cake tray and tank Correct coffee operation with measurement of cake thickness comprised between 11 and 13 mm with new grinder in 60 m...

Reviews: