OBSERVED FAULTS, CAUSES AND REMEDIES
OBSERVED FAULT
CAUSE
REMEDY
• Check mains
• Check proper positioning and functioning of
•
switch
• Check fuse
• Wrong setting of room thermostat or other
•
control
• Check correct setting of heater control.
•
If thermostat, make sure selected temperature
•
is higher than room temperature
• Thermostat or other control defective
• Replace control device
• Electrical motor defective
• Replace electrical motor
• Electrical motor bearings defective
• Replace electrical motor bearings
• Burned out condenser
• Replace condenser
• Check connection of H.T. Ieads to electrodes
•
and transformer
• Check electrodes setting (see scheme
•
“REGULATION OF ELECTRODES”)
• Check electrodes for cleanliness
• Replace H.T. transformer
• Flame control box defective
• Replace control box
• Photocell defective
• Clean or replace photocell
• Check state of motor-pump plastic coupling
• Check fuel line system including fuel filter for
•
possible leaks
• Clean or replace oil nozzle
• Check electrical connection
• Check thermostat LI
• Clean or replace solenoid
• Make sure air inlet and outlet are free
• Check setting of combustion air flap
• Clean burner disc
• Too much combustion air
• Check setting of combustion air flap
• Drain fuel in tank with clean fuel
• Clean oil filter
• Air leaks in fuel circuit
• Check the seals on the ducts and the diesel filter
• Check pump pressure
• Clean or replace fuel nozzle
• Check pump pressure
• Replace nozzle
• Heater does not stop
• Solenoid defective
• Replace solenoid coil or complete solenoid
If heater still not working properly, please revert to nearest authorized dealer.
• Not enough combustion air
• Fuel contaminated or contains water
• Not enough fuel at burner
• Too much fuel at burner
• Motor starts, heater emits smoke
• No electrical current
• Motor does not start, no ignition
• Electric ignitor defective
• Not enough or no fuel at all at burner
• Motor starts, no ignition or cuts out
• Solenoid defective
GB
Summary of Contents for HEIMDAL45
Page 2: ......
Page 20: ...19 RU 22 3 13 1 13 3 s st ta an nd d b by y 1 13 3 13 10 A...
Page 21: ...14 ON 15 2 2 SPEED 18 I S II S I 13 1 2 13 3 14 0 90 19 50 20 RU B...
Page 22: ...21 RU...
Page 26: ......
Page 27: ......