13
WATER SUPPLY:
Proceed as described:
Open the cap (7) and refill the tank with water (check
the water level on the side label).
Close the cap.
You will hear the pump starting to work, please wait a
few seconds and then re-start your cleaning operation
with steam.
ACCESSORIES AND USE
:
FLEXIBLE HOSE AND HANDLE
To connect the accessories, release steam and
detergent, it is necessary to use the flexible hose.
The product is designed to ensure maximum
practicality.
BRUSHES
These brushes must be connected to the STEAM
LANCE. They are used to remove resistant dirt and
for deep cleaning, even in the corners or small
spaces. Choose the most suitable type (ø28, 40, 60
mm) according to the surface to be treated.
TANK SUCTION ACCESSORY
Accessory to be connected to
the flexible hose to vacuum
and clean the tanks.
MANTAINANCE
(End user)
* Always remove the plug before cleaning
or carrying out operations on the machine.
* End user must not open or dismantle the
machine
.
For the safety of the operator and to always ensure a
perfect performance, we recommend the following
checks and maintenance:
AFTER EVERY USE:
For a correct cleaning, it is advice to clean the machine
and its accessories with a clean cloth moistened only
with a few drops of water. Do not use alcohol or other
solvents, they may damage the plastics and
components.
To maintain efficient and easy to couple the
accessories, check the o-ring seal (
steam sealing
gaskets
) and possibly wet them with a little silicone
grease.
VACUUM FUNCTION: when you finish to vacuum, it is
advisable to vacuum some water to clean the conducts
and the filter. Afterwards, dry the bucket or do not totally
close it so that it will dry itself.
PERIODICALLY:
Periodically check that the power cord does not show
signs of wear or aging. If it is damaged, it is absolutely
necessary to get it replaced by specialized personnel
before being able to re-use the appliance again.
BOILER CLEANING
(End user)
Once a year a check and boiler cleaning must be
carried out in our authorized centers.
RINSE
: It’s recommended at least every 50 hours of
operation or 2 months.
a) DISCHARGE: The machine must be cold or definitely
discharged from the steam pressure and the plug
disconnected (See manometer 4). It is possible to use
the Boiler-Off switch (6) to completely discharge the
steam from the boiler: With the machine switched on,
turn off the Boiler-Off switch (6), insert the hose into the
machine's socket (5) and pressing the button (13)
completely dispense all the residual steam in the boiler.
(keep the dispensing active for a further minute after the
apparent steam escapes to ensure that the boiler has
been completely emptied, see manometer 4). With the
help of a wrench CH 21 unscrew the cap (15) placed
under the machine in correspondence of the boiler (see
image). After having taken off the cap, shake slightly
the machine to let the water and the dissolved
limestone out.
When the boiler is empty, clean and close carefully the
cap tightening it with the wrench.
b) FILLING: Fill the water tank (7), turn the machine on
and make it start again, waiting for the boiler to be re-
charged again.
(
att
: it may be that during the first charge cycle, the
“end of water” light turns on and you need to shut
down/restart the machine to complete the load)