EN
page 34
6.3 Installation
6.3.1 Positioning the machine
Remove the packing with care.
Lift the machine as described in par.
6.1.1 Handling the product
.
Position the machine as shown on the installation diagram (lay-out) approved at the time
of the offer.
Maintain a minimum distance of about 50 mm from the walls, so that motors are ventilated.
Install suction hoods to assure proper ventilation of the room, in order to eliminate steam
and excessive humidity.
Check that the machine is properly levelled, by adjusting the legs.
Make sure the machine is not standing on the power cable or on the
fi
lling/drain hoses.
Level the machine
fl
at, by adjusting the support feet.
6.3.2 Electrical
connection
The electrical connection shall be carried out in accordance to the local laws in force.
The machine has a connection at the back, indicated by the symbol
, that is meant to
link the steel structure and masses among different apparatuses, to prevent electro-static
electrical shocks.
The electrical supply cable must be new,
fl
exible, and according to "har" H07RN-F or a local
valid equivalent. The cable size is dimensioned according to the power.
Should the electrical supply cable get damaged it shall be changed by the Manufacturer, or his
Authorized Service, or other technician with equivalent quali
fi
cation, to prevent any risk.
If the machine is
fi
tted with a three-phase pump, check the correct motor rotation (right ro-
tation as per arrow on the casing). This is not needed if the pump is a single-phase model
(standard).
6.3.3 Water
connection
Connect the water in-feed hose, given with the machine, to a ¾” water supply tap.
Connect the machine draining pipe to the connection located at rear, under the back-panel,
in such a way that water
fl
ows freely (therefore ensuring a minimum slope). If the water
cannot be discharged to a level below the machine drain, it is advisable to install a drain
pump (supplied on request).
Maximum drain height = cm. 50 (see pict. 7).
The drain tube shall always be connected to a siphon in order to prevent the release of
odors.
In those machines equipped with “water softener” the water supply temperature shall not
exceed 40°C, to avoid damages to the
fi
lters’ resins.
6.3.4 Start-up
At installation engineer’s care.
MAX 0,5m
pict. 7
2
3
1
pict. 6