4.1 System integration
A PROFINET IO General Station Description (PN-GSD) file is required for system integration.
The file contains a device description written in GSD Markup Language (GSDML).
The GSD file is available for download from the KROHNE website.
4.1.1 Default communication settings
Unless it is ordered with customised settings the device is shipped with the following default
settings:
4.1.2 Device discovery and identification (DCP signal)
To identify the device, the DCP signal service can be used. While a DCP signal is active the
Network Status LED is flashing yellow at 1 Hz (for details refer to
Network status
on page 16).
PROFINET IO version
2.3.3
Manufacturer ID
0x45 = 69 = KROHNE
Device ID
0x4512 = 17682 = MFC 400
GSD file
GSDML-V2.32-KROHNE-MFC400-YYYYMMDD.xml
Table 4-1: Device description
Parameter
Value
Description
Device Name
(NameOfStation)
Empty / not set
IP Address
000.000.000.000
Empty / not set
Subnet Mask
000.000.000.000
Empty / not set
Default Gateway
000.000.000.000
Empty / not set
Table 4-2: Default communication settings