7.5 Replace valve parts
1.
Chapter 7.4 ‘Clean the diaphragm pump’ on page 30
).
2.
Make sure that the compressed air supply is switched off and secured against a restart.
3.
Reduce the material pressure by activating the extraction point.
Fig. 9: Valve parts
4.
Unscrew the hexagon screws ( Fig. 9/1).
5.
Remove the bridge ( Fig. 9/2).
6.
Remove the flat seals ( Fig. 9/3), ball cages ( Fig. 9/4), valve balls ( Fig. 9/5) and the valve
seat ( Fig. 9/6).
7.
Check all parts for damage and wear and replace them as necessary.
8.
Chapter 7.6 ‘Replace the diaphragm’ on page 33
Diaphragm pump MP-520
ENGLISH
Article No. 200-0216, 200-0330
GB–31