5.5 Dismantling the diaphragm pump
WARNING!
Risk of injury through a pressurized diaphragm pump!
Uncontrollably leaking pressurized fluids or compressed air can cause serious injuries.
Note:
–
Prior to any work on the device, all compressed-air lines must be closed and secured
against a restart.
–
Never point compressed air at living beings.
–
Activate the extraction point to depressurize the diaphragm pump.