Setting the Machine Number: 

 

When using a single 

VS-88HDxl

 unit, set the unit to Machine # 1.  

 

When connecting more than one 

VS-88HDxl

 unit set a unique Machine # for each unit. The units do not have to be 

numbered sequentially. The master unit must be set to Machine #1. 

To set the machine # for each unit, set the DIP switches according to the relevant row in the following table: 

Machine # 

DIP-SWITCH 

 

 

1 (Single or master 
unit) 

OFF or ON 

OFF  

OFF  

OFF  

OFF 

ON 

OFF 

OFF 

ON 

ON 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

ON 

OFF 

ON 

OFF 

OFF 

ON 

ON 

OFF 

ON 

ON 

ON 

OFF 

OFF 

OFF 

OFF 

ON 

ON 

OFF 

OFF 

ON 

10 

OFF 

ON 

OFF 

ON 

11 

ON 

ON 

OFF 

ON 

12 

OFF 

OFF 

ON 

ON 

13 

ON 

OFF 

ON 

ON 

14 

OFF 

ON 

ON 

ON 

15 

ON 

ON 

ON 

ON 

 

Note

: After changing the machine #, the unit must be reset by turning it OFF and ON. 

Setting the RS-485 Line Termination: 

 

The 

RS-485 TERM DIP

 switch on the first and last units on the RS-485 line must be set to 

ON (terminated) and all other units must be set to OFF (not terminated).  

Note

: The master unit may be located at any part of the line.  

 

Setting the Genlock Video Signals: 

To set the Genlock video signals according to timing of the Genlock reference input: 

1.  Connect the Genlock cable. 

2.  Press and hold, for 3 seconds, the relevant 

IN SELECT

 button according to the table: 

IN SELECT Button 

Genlock Setting 

1080i/p @60Hz 

1080i/p @50Hz 

720p @60Hz 

PAL @50Hz 

NTSC @60Hz 

 

The Genlock setting changes and the new setting is displayed in the

 INPUT

 display.

 

 

 

To achieve specified extension distances, use the recommended Kramer cables available a

www.kramerav.com/product/VS-88HDxl

Using third-party cables may cause damage! 

 

Step 5:  Connect power 

Connect the power cord to 

VS-88HDxl

 and plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

  Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. 

  To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.

 

 

  

  