Step 6:  Operate VS-88HDxl 

IR remote control: 

RS-232/RS-485 and Ethernet: 

 

 

RS-232 

 

Protocol 2000 

Protocol 3000 

Baud Rate:  

9600 

Baud Rate:  

115200 

Data Bits:  

Data Bits:  

Stop Bits:  

Stop Bits:  

Parity:  

None 

Parity:  

None 

Command Format: 

HEX 

Command Format: 

ASCII 

 

Example: (Switch video input 2 to output 4):  

#V 2>4<CR> 

Switching Protocol 

 

P2000 -> P3000 

P3000 -> P2000 

Command: 

0x38, 0x80, 0x83, 0x81 

Command: 

#P2000<CR> 

Front Panel:  Press and hold LOCK and OUT 3 

simultaneously 

Front Panel: 

Press and hold LOCK and OUT 2 
simultaneously 

Default Ethernet Parameters 

IP Address:  

192.168.1.39  

UDP Port #:  

50000 

Subnet mask:  

255.255.0.0 

TCP Port #:  

5000 

Default gateway:  

0.0.0.0. 

 

 

 

Power On Display: 

When 

VS-88HDxl

 is powered on, the display briefly shows the 4-

digit firmware version number and the genlock timing setting 
before showing the normal operating display. 

 
Opration Modes: 

VS-88HDxl

 

can operate in the following two modes:  

  At Once 

– pressing buttons on the front panel 

immediately executes a command. 

  Confirm 

– pressing buttons on the front panel does not 

execute a command until the 

TAKE

 button is pressed, 

to protect against incorrect switching. The mode also 
enables keying in several commands and then, 
simultaneously executing them by pressing the TAKE 
button. 

To toggle between At Once and Confirm modes, press the 

TAKE

 

button when there are no commands pending. 

Note

: The 

TAKE

 button remains lit in Confirm mode. 

To simultaneously execute several commands in Confirm mode: 

1.  Press the required OUT-IN combinations in sequence. 

The 

INPUT

 display flashes. 

2.  Press the 

TAKE

 button to confirm all the actions. 

The actions are executed and the 7-segment display stops 
flashing. 

 

Storing Configurations: 

You can save up to 16 input/output configurations in the 

VS-88HDxl

 

memory and load them as presets. 

To save the current configuration: 

1.  Press the 

STO

 button. 

The 

STO

 button flashes. 

2.  Press one of the 

IN/OUT SELECT

 buttons. 

The current configuration is saved in the memory for the 
selected button. 

To load an input/output configuration: 

1.  Press the 

RCL

 button. 

The RCL button flashes. 

2.  Press the 

IN/OUT

 

SELECT

 button that corresponds to the 

required configuration.  
The selected preset configuration is loaded from memory.  

Note

: Recalling an invalid preset activates an error indication (the 

STO

RCL

LOCK

, and 

TAKE

 buttons flash).  

If you cannot remember which of the 

IN/OUT SELECT

 buttons 

corresponds to the required configuration, set 

VS-88HDxl

 to 

Confirm mode and manually scan all the configurations until you 
locate it.

 

 