Step 6: Operate VS-88HDxl
IR remote control:
RS-232/RS-485 and Ethernet:
RS-232
Protocol 2000
Protocol 3000
Baud Rate:
9600
Baud Rate:
115200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example: (Switch video input 2 to output 4):
#V 2>4<CR>
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel: Press and hold LOCK and OUT 3
simultaneously
Front Panel:
Press and hold LOCK and OUT 2
simultaneously
Default Ethernet Parameters
IP Address:
192.168.1.39
UDP Port #:
50000
Subnet mask:
255.255.0.0
TCP Port #:
5000
Default gateway:
0.0.0.0.
Power On Display:
When
VS-88HDxl
is powered on, the display briefly shows the 4-
digit firmware version number and the genlock timing setting
before showing the normal operating display.
Opration Modes:
VS-88HDxl
can operate in the following two modes:
•
At Once
– pressing buttons on the front panel
immediately executes a command.
•
Confirm
– pressing buttons on the front panel does not
execute a command until the
TAKE
button is pressed,
to protect against incorrect switching. The mode also
enables keying in several commands and then,
simultaneously executing them by pressing the TAKE
button.
To toggle between At Once and Confirm modes, press the
TAKE
button when there are no commands pending.
Note
: The
TAKE
button remains lit in Confirm mode.
To simultaneously execute several commands in Confirm mode:
1. Press the required OUT-IN combinations in sequence.
The
INPUT
display flashes.
2. Press the
TAKE
button to confirm all the actions.
The actions are executed and the 7-segment display stops
flashing.
Storing Configurations:
You can save up to 16 input/output configurations in the
VS-88HDxl
memory and load them as presets.
To save the current configuration:
1. Press the
STO
button.
The
STO
button flashes.
2. Press one of the
IN/OUT SELECT
buttons.
The current configuration is saved in the memory for the
selected button.
To load an input/output configuration:
1. Press the
RCL
button.
The RCL button flashes.
2. Press the
IN/OUT
SELECT
button that corresponds to the
required configuration.
The selected preset configuration is loaded from memory.
Note
: Recalling an invalid preset activates an error indication (the
STO
,
RCL
,
LOCK
, and
TAKE
buttons flash).
If you cannot remember which of the
IN/OUT SELECT
buttons
corresponds to the required configuration, set
VS-88HDxl
to
Confirm mode and manually scan all the configurations until you
locate it.