Feature 

Function 

17 

PROG/RS-485 TERM

  

DIP Switches

 

PROG 

DIP switch enables microcontroller firmware upgrade. 

RS-485 TERM

 DIP switch terminates the RS-

485 line with a 120Ω load.  

18 

RS-485 

Terminal Block Port

 

Connect to a RS-485 control device (see Step 4). 

19 

ETHERNET 

RJ-45 Connector

 

Connects to a PC or other serial controller through computer networking LAN. 

20 

MACH # 

DIP Switches 

Use the set the Machine number of the unit (see Step 4).  

21 

ETH RESET

 Button 

Press to reset to factory default definitions:  
IP number 

 192.168.1.39, Mask 

– 255.255.0.0, Gateway – 0.0.0.0 

22 

OUTPUT 

BNC Connectors 

Connect to the serial digital video acceptors. 

23 

REMOTE IR 

3.5mm Mini Jack

 

Connect to an external IR receiver unit for controlling the machine via an IR remote control 
(instead of using the front panel IR receiver). 

24  Power Connector with Fuse 

Connect to the electricity mains using the power cord. 

25  Power Switch 

Turns the power to the unit ON and OFF. 

 

Step 3:  Mount VS-88HDxl 

To rack mount the machine, attach both rack ears 
(by removing the screws from each side of the 
machine and replacing those screws through the 
rack ears) or place the machine on a table.  

 

 

  Ensure that the environment (e.g., maximum ambient temperature & 

air flow) is compatible for the device. 

  Avoid uneven mechanical loading. 

  Appropriate consideration of equipment nameplate ratings should be 

used for avoiding overloading of the circuits. 

  Reliable earthing of rack-mounted equipment should be maintained. 

 

Step 4:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

VS-88HDxl

 

 

RS-232 Connection: 

Use a 9-wire straight cable and connect only pin 2 to pin 2, pin 3 to pin 3, and pin 5 to pin 5 to the RS-232 9-pin D-sub port on 
your PC. 

Note:

 A null-modem adapter/connection is not required. 

RS 485 Connection: 

You can operate the 

VS-88HDxl

 via the RS-485 port from a distance of up to 1200m (3900ft).  

To connect a control device with a RS-485 port to the 

VS-88HDxl

1.  Set the 

VS-88HDxl

 RS-485 machine number and bus termination. 

2.  Connect the A (+) pin, B (

–) pin, and G pin on the RS 485 port of the PC to the corresponding pins on the RS 485 port 

on the rear panel of the 

VS-88HDxl

. Note: Pin G may be connected to the shield, if required. 

  