Kramer Electronics Ltd.
VS-88H2
–
Protocol
3000 Commands
77
Function
Description
Syntax
Parameters/Attributes
Example
TUNNEL-
CTRL
LEGACY COMMAND.
Send an
asynchronous
command to a remote
Step-in equipment.
COMMAND
#TUNNEL-CTRL
io_mode
,
io_index
,
cmd_name
<CR>
FEEDBACK
None
io_mode
– Input/Output
0
– Input
1
– Output
io_index
– Number that indicates
the specific input or output port:
1-N (N= the total number of input or
output ports)
cmd_name
– Command to send to
the Step-in client
LEGACY COMMAND:
#TUNNEL-CTRL
1
,
1
,
1
<C
R>
UART
Set com port
configuration.
In the FC-2x the
serial port is
selectable to RS-232
or RS-485 (usually
serial port 1).
If Serial is configured
when RS-485 is
selected, the RS-485
UART port
automatically
changes.
The command is
backward compatible,
meaning that if the
extra parameters do
not exist, FW goes to.
RS-232.
Stop_bits 1.5 is only
relevant for 5
data_bits.
COMMAND
#UART
com_id
,
baud_rate
,
data_bits
,
parity
,
stop_bits_mode
,
s
erial_type
,
485_term
<CR>
FEEDBACK
~nn@UART
com_id
,
baud_rate
,
data_bits
,
parity
,
stop_bits_mod
e
,
serial_type
,
485_term
<CR><LF>
com_id
– 1 to n (machine
dependent)
baud_rate
– 9600 - 115200
data_bits
– 5-8
parity
– Parity Type
0
– No
1
– Odd
2
– Even
3
– Mark
4
– Space
stop_bits_mode
– 1/1.5/2
serial_type
– 232/485
0
– 232
1
– 485
485_term
– 485 termination state
0
– disable
1
– enable
(optional - this exists only when
serial_type
is 485)
Set baud rate to 9600, 8
data bits, parity to none and
stop bit to 1:
#UART?
1
,
9600
,
8
,
node
,
1
<CR>
UART?
Get com port
configuration.
In the FC-2x the
serial port is
selectable to RS-232
or RS-485 (usually
serial port 1).
If Serial is configured
when RS-485 is
selected, the RS-485
UART port
automatically
changes.
The command is
backward compatible,
meaning that if the
extra parameters do
not exist, FW goes to.
RS-232.
Stop_bits 1.5 is only
relevant for 5
data_bits.
COMMAND
#UART?
com_id
<CR>
FEEDBACK
~nn@UART
com_id
,
baud_rate
,
data_bits
,
parity
,
stop_bits_mod
e
,
serial_type
,
485_term
<CR><LF>
com_id
– 1 to n (machine
dependent)
baud_rate
– 9600 - 115200
data_bits
– 5-8
parity
– Parity Type
0
– No
1
– Odd
2
– Even
3
– Mark
4
– Space
stop_bits_mode
– 1/1.5/2
serial_type
– 232/485
0
– 232
1
– 485
485_term
– 485 termination state
0
– disable
1
– enable
(optional - this exists only when
serial_type
is 485)
Get baud rate to 9600, 8
data bits, parity to none and
stop bit to 1:
#UART?
1
<CR>
VERSION?
Get firmware version
number.
COMMAND
#VERSION?
<CR>
FEEDBACK
~nn@VERSION
firmware_version
<CR><LF>
firmware_version
–
XX.XX.XXXX where the digit groups
are: major.minor.build version
Get the device firmware
version number:
#VERSION?
<CR>
VID
LEGACY COMMAND.
Set video switch state.
The GET
command identifies
input switching on
Step-in clients.
The SET command is
for remote input
switching on Step-in
clients (essentially via
by the Web).
This is a legacy
command. New Step-
in modules support
the ROUTE
command.
COMMAND
#VID
in_id>out_id
<CR>
FEEDBACK
~nn@VID
in_id>out_id
<CR><LF>
in_id
– Indicates the ID of the
input:
1-n (n= the total number of inputs)
>
– Connection character between
in and out parameters
out_id
–Output number
* for all outputs
Switch HDMI IN 1 to HDMI
OUT 3:
#VID
1>3
<CR>