VS-3232DN - Using the Configuration Menus
31
It is necessary to have a display/device connected to the output from
which you want to read the EDID. Failure to do so results in the
default EDID being written to storage.
To assign an EDID to between one and eight inputs:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
The following is displayed:
SETUP EDID
ENT to View EDID and Set EDID
3. Press ENT.
The current EDID matrix configuration is displayed.
4. Using the numeric keys, enter the input in which to store the EDID (in this
example, 08), and enter the output (in this example, 05) from which to read
the EDID.
The following is displayed:
01 02 03 04 05 06 07 08
05 out05 => in08
The TAKE button flashes.
5. Repeat Step 4 for up to eight inputs.
6. Press TAKE.
The EDID is stored and passed through to the input.
The display reverts to the output/input display.
To view the EDID assignments:
1. Press MENU.
The Setup Menu options are displayed.