![Kramer VS-3232A User Manual Download Page 67](http://html.mh-extra.com/html/kramer/vs-3232a/vs-3232a_user-manual_2001316067.webp)
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Protocols
62
"X": Connect on a LEVEL
The command "
X
" is used to request that a connection be made on a user defined
level. It must be followed by an output number, a comma, an input number, a comma
and a level number.
The level number must be identical to the machine number set by the DIP-switches
on the rear panel.
The command:
** X2,29,3!!
connects output 2 to input 29 in router machine number 3 and returns the following
string:
** OK !!
indicating that the router performed the requested connection.
The command:
** X2,17,1 Y32,-,1 X7,6,1!!
connects output 2 with input 17, disconnects output 32 and connects output 7 with
input 6 in router Machine number 1 and returns the following string:
** OK !!
"P": Preset a Salvo Connect Sequence
The command "
P
" is used to set up a
salvo
, which is a series of connect commands
for later execution with the "T" command.
The command:
**P29!!
stores full matrix setup in address 29 (1-59) of non-volatile memory and returns the
following string:
** OK !!
"T": Trigger a Salvo Connect Sequence
The command "
T
" is used to recall a
salvo
, which is a series of connect commands
for previously stored status with the "
P
" command
The command:
**T29!!
restores full matrix setup from address 29 (1-59) of non-volatile memory and return
the following string:
** OK !!