KRAMER: SIMPLE CREATIVE TECHNOLOGY
The MENU Commands
42
9.4 Selecting the Interface REPLY Configuration
Table 12
summarizes the interface REPLY configuration options:
Table 12: Interface REPLY Configuration Menu
Press:
To select:
After the change:
1
Turn reply ON
All the interfaces that are set to ON accept and execute commands and also
reply
2
Never REPLY
All the interfaces that are set to ON accept and execute commands but do not
reply
9.5 Selecting the PROTOCOL Configuration
Table 13
summarizes the PROTOCOL configuration options:
Table 13: PROTOCOL Configuration Menu
Press:
To select:
After the change, the LCD displays:
1
HEXadecimal
, for setting the protocol
1
to HEX KRAMER-2000
Communication protocol set to HEX KRAMER-
2000
2
ASCII
, for setting the protocol
1
to
ASCII – SIERRA
Communication protocol set to ASCII – SIERRA
9.6 Selecting the Store DEFAULT Setup Configuration
2
This option in the configuration menu lets you store the current setup to the
default setup, so that by pressing the DEFAULT SETUP button on the front
panel you can recall the default setup (so called UNITY setting).
After pressing the ENT button, the TAKE button blinks and the following
message appears on the display:
current matrix stage is OKAY?
press TAKE to confirm
After pressing the blinking TAKE button, the display shows:
current matrix stage
stored as DEFAULT setup
1 See section 12 for a description of the protocols
2 See section 8.6