background image

Your VS-121HCA Stereo Audio S/PDIF Switcher 

 

Table 1: VS-121HCA Front Panel Features 

Feature 

Function 

IR Receiver

 

The red LED is illuminated when receiving signals from the 

Infrared remote control transmitter 

POWER

 Switch 

Illuminated switch for turning the unit ON or OFF 

Input Selector

 

Buttons 

Select the audio input (1 to 12) to switch to the outputs 

PANEL LOCK

 Button

 

Disengages/engages the front panel buttons 

Table 2: VS-121HCA Rear Panel Features 

Feature 

Function 

S/PDIF INPUT 

 RCA Connectors 

Connect to the digital audio source (1 to 12) 

S/PDIF OUT

 RCA Connector

 

Connect to digital audio acceptor 

ANALOG AUDIO IN 

Terminal Blocks

 

Connect to analog audio source (IN1 to IN12) 

ANALOG AUDIO OUT 

Terminal 

Block

 

Connect to analog audio acceptor 

ETHERNET 

RJ-45 Connector

 

Connects to the PC or other Controller through computer 

networking LAN 

10 

REMOTE IR 

3.5mm Mini Jack

 

Connect to an external IR receiver unit for controlling the machine 

via an IR remote controller (instead of using the front panel IR 
receiver)

1

11 

 

RS-485 

Terminal Block Port

 

Pins B (-) and A (+) are for RS-485; Pin G may be connected to 

the shield (if required) 

12 

Setup DIP-switches 

DIP-switches for setup of the unit (1 to 4 are for setting the 

machine number; and 8 is for RS 485 termination) 

13 

Power Connector with Fuse 

AC connector enabling power supply to the unit 

14 

ETH PROG 

Button 

Push in to upgrade ETH firmware (see section 

 9.2

); 

release for normal operation 

15 

ETH FACTORY RESET

 Button 

Press to reset to factory default definitions

2

16 

IP number 

 192.168.1.39 

Mask – 255.255.255.0 
Gateway – 192.168.1.1 

FLASH PROG 

Button

 

Push in

3

 9.1.1

 for “Program” to upgrade the switcher microcontroller to 

the latest Kramer firmware (see

 

section 

), or release (the 

factory default) for normal operation 

17 

RS-232 

9-pin D-sub (F) Port 

Connect to the PC or the Remote Controller via a null-modem 

connection 

 
 
 
 
 

                                                          

 

1  Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the VS-121HCA (only if the 

internal IR connection cable has been installed) 

2 Turn the machine OFF, then turn the machine ON while pressing the FACTORY RESET button. The unit powers up and 

loads its memory with the factory default definitions  

3 Using a screwdriver if required 

Summary of Contents for VS-121HCA

Page 1: ...Kramer Electronics Ltd USER MANUAL Model VS 121HCA 12 x 1 Stereo Audio S PDIF Switcher...

Page 2: ...Crossover Cable 12 7 4 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable 13 7 4 3 Configuring the Ethernet Port 13 7 5 Operating via the Infrared Remote Controller 13 7 5 1 Adjus...

Page 3: ...igure 10 Splash Screen 19 Figure 11 Atmel Flip Window 20 Figure 12 Device Selection Window 20 Figure 13 Device Selection Window 21 Figure 14 Loading the Hex 21 Figure 15 RS 232 Window 22 Figure 16 Atm...

Page 4: ...em adapter and rack ears 3 RC IR2 Infrared remote control transmitter including the required battery and a separate user manual4 This user manual4 2 Getting Started We recommend that you Unpack the eq...

Page 5: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Page 6: ...usted by IR remote control or RS 232 The volume settings are saved in non volatile memory The ability to operate it in tandem with the VS 121HC Operate the VS 121HCA using the front panel buttons or r...

Page 7: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Your VS 121HCA Stereo Audio S PDIF Switcher 4 Figure 1 VS 121HCA 12 x 1 Stereo Audio S PDIF Switcher...

Page 8: ...IR receiver 1 11 RS 485 Terminal Block Port Pins B and A are for RS 485 Pin G may be connected to the shield if required 12 Setup DIP switches DIP switches for setup of the unit 1 to 4 are for settin...

Page 9: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the VS 121HCA in a Rack 6 5 Installing the VS 121HCA in a Rack This section provides instructions for rack mounting the unit...

Page 10: ...layer to the IN 10 terminal block connector 2 Connect the outputs to acceptors 1 or 2 output devices can be connected1 One S PDIF output acceptor for example a DAT recorder to the S PDIF OUT RCA conne...

Page 11: ...ee section 7 1 The RS 232 port see section 7 2 The RS 485 port see section 7 3 An Ethernet network see section 7 4 The RC IR2 remote control transmitter1 7 5 see section This section also describes Ho...

Page 12: ...hrough the RS 232 port For a description of the serial commands see section 11 To operate your device using serial commands you need to install Kramer s control software that can be downloaded from th...

Page 13: ...ethod A above only requires pins 2 3 and 5 to be connected you are free to decide whether to connect only these 3 pins or all 9 pins Figure 4 Straight Cable RS 232 Connection with a Null Modem Adapter...

Page 14: ...eration the RS 485 line must be terminated at both ends The master unit may be located at any part of the line but when it is at the end of the line the termination switch must be set ON To set line t...

Page 15: ...e VS 121HCA to the Ethernet port on your PC via a crossover cable with RJ 45 connectors This type of connection is recommended for identification of the factory default IP Address of the VS 121HCA dur...

Page 16: ...h RJ 45 connectors 7 4 3 Configuring the Ethernet Port After connecting the Ethernet port you must install and configure the port For detailed instructions on how to install and configure your Etherne...

Page 17: ...just the input volume on any of the individual input channels The setting is saved in non volatile memory and remains even after the unit is turned OFF and ON To adjust the volume 1 On the remote cont...

Page 18: ...connecting more than one VS 121HCA set the first machine only when connected via RS 232 to be machine number 1 The other VS 121HCA units must each be set to a unique machine number between 2 and 16 Ta...

Page 19: ...or the Ethernet ports of the VS 121HC To set the VS 121HCA to operate in tandem with the VS 121HC 1 Set the machine number on both units to 1 DIP switches 1 2 3 and 4 are set OFF 2 Connect the VS 121...

Page 20: ...AUDIO 2nd HARMONIC 0 02 1kHz POWER SOURCE 100 240V AC 50 60Hz 115V AC U S A 8VA DIMENSIONS 19 x 7 x 1U W D H rack mountable WEIGHT 2 6kg 8lbs approx ACCESSORIES Power cord null modem adapter rack ears...

Page 21: ...PC to the RS 232 port see section 9 1 2 Install the latest firmware see section 9 1 3 9 1 1 Downloading from the Internet To download the latest file1 1 Go to our Web site at from the Internet www kr...

Page 22: ...ng the Device Firmware To install the firmware perform the following steps 1 Double click the desktop icon Shortcut to FLIP EXE The Splash screen appears1 Figure 10 Splash Screen 2 After a few seconds...

Page 23: ...w by Pressing the keyboard shortcut key F2 or Choosing the Select command from the Device menu or Pressing the integrated circuit icon in the upper right corner of the window The Device Selection wind...

Page 24: ...Upgrading the VS 121HCA Firmware 21 AT89C51RD2 T89C51RD2 Figure 13 Device Selection Window 5 Click OK 6 From the File menu select Load Hex Figure 14 Loading the Hex...

Page 25: ...ication RS232 command from the Settings menu or press the keys Alt SCR The RS232 window appears 9 Change the COM port settings according to the configuration of your computer and select the 9600 baud...

Page 26: ...S 121HCA 14 If required disconnect the null modem adapter from the VS 121HCA 15 Press the FLASH PROG button on the front panel of the VS 121HCA outward to its original position see Figure 1 16 Power O...

Page 27: ...firmware file to a folder for example C Program Files KFR Upgrade 4 Install the KFR Programmer Application 9 2 2 Connecting the PC to the RS 232 Port To connect a PC to the RS 232 port of the VS 121H...

Page 28: ...lect the required COM Port1 3 Press the File button to select the s19 firmware file included in the package 4 Press the Send button to download the file The Send button lights red 5 Wait until the dow...

Page 29: ...4 02 84 81 81 IN 5 02 85 81 81 IN 6 02 86 81 81 IN 7 02 87 81 81 IN 8 02 88 81 81 IN 9 02 89 81 81 IN 10 02 8A 81 81 IN 11 02 8B 81 81 IN 12 02 8C 81 81 Table 8 VS 121HCA Increase Decrease Audio Gain...

Page 30: ...INSTRUCTION NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched...

Page 31: ...ber of outputs 3 number of setups 1 for video 2 for audio 3 for SDI 14 NOTES on the above table NOTE 1 When the master switcher is reset e g when it is turned on the reset code is sent to the PC If th...

Page 32: ...ware version number Again the reply would be the decimal value of the INPUT and OUTPUT the INPUT representing the number in front of the decimal point and the OUTPUT representing the number after it F...

Page 33: ...er lightning orotheractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct...

Page 34: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...