Your VS-121HCA Stereo Audio S/PDIF Switcher
5
Table 1: VS-121HCA Front Panel Features
#
Feature
Function
1
IR Receiver
The red LED is illuminated when receiving signals from the
Infrared remote control transmitter
2
POWER
Switch
Illuminated switch for turning the unit ON or OFF
3
Input Selector
Buttons
Select the audio input (1 to 12) to switch to the outputs
4
PANEL LOCK
Button
Disengages/engages the front panel buttons
Table 2: VS-121HCA Rear Panel Features
#
Feature
Function
5
S/PDIF INPUT
RCA Connectors
Connect to the digital audio source (1 to 12)
6
S/PDIF OUT
RCA Connector
Connect to digital audio acceptor
7
ANALOG AUDIO IN
Terminal Blocks
Connect to analog audio source (IN1 to IN12)
8
ANALOG AUDIO OUT
Terminal
Block
Connect to analog audio acceptor
9
ETHERNET
RJ-45 Connector
Connects to the PC or other Controller through computer
networking LAN
10
REMOTE IR
3.5mm Mini Jack
Connect to an external IR receiver unit for controlling the machine
via an IR remote controller (instead of using the front panel IR
receiver)
1
11
RS-485
Terminal Block Port
Pins B (-) and A (+) are for RS-485; Pin G may be connected to
the shield (if required)
12
Setup DIP-switches
DIP-switches for setup of the unit (1 to 4 are for setting the
machine number; and 8 is for RS 485 termination)
13
Power Connector with Fuse
AC connector enabling power supply to the unit
14
ETH PROG
Button
Push in to upgrade ETH firmware (see section
9.2
);
release for normal operation
15
ETH FACTORY RESET
Button
Press to reset to factory default definitions
2
16
:
IP number
−
192.168.1.39
Mask – 255.255.255.0
Gateway – 192.168.1.1
FLASH PROG
Button
Push in
3
9.1.1
for “Program” to upgrade the switcher microcontroller to
the latest Kramer firmware (see
section
), or release (the
factory default) for normal operation
17
RS-232
9-pin D-sub (F) Port
Connect to the PC or the Remote Controller via a null-modem
connection
1 Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the VS-121HCA (only if the
internal IR connection cable has been installed)
2 Turn the machine OFF, then turn the machine ON while pressing the FACTORY RESET button. The unit powers up and
loads its memory with the factory default definitions
3 Using a screwdriver if required