7.2 Connecting the REMOTE Connector
You may reverse the presently routed connection by using the remote control
contact closure
1
. To do so, connect the appropriate channel
2
pin on the
REMOTE terminal block connector to the G (Ground) pin
3
, as Figure 10
illustrates. You can also connect several channels to G.
The input which was
not routed in channel C
is now routed to the
output
The non-routed inputs
in channels A, B and D
are now selected to
their outputs
Figure 10: Remote Terminal Block Connector
1 For example, if channel A inputs are set according to the second example in Table 10, input 1 will be routed to the output
even if it does not have an active signal
2 Channel A, B, C and/or D
3 Note that the connection should be permanent, since the VP-214DS will revert to an automatic switcher when the
connection is removed