background image

Kramer Electronics Ltd. 

 

UTBUS-1xl 

– Installing the UTBUS-1xl 

 

Installing the UTBUS-1xl 

This section describes the 

UTBUS-1xl

 installation process: 

 

Installing the Required Wall Plate Inserts

 on page 

6

 

Installing the Power Socket

 on page 

6

 

Installing the Cables

 on page 

7

 

Securing the UTBUS-1xl Enclosure to the Table

 on page 

7

Installing the Required Wall Plate Inserts 

By default, the mounting surface includes a power socket opening and four blank plates for 
optional video, audio and network connectors. Each blank plate can be removed and replaced 
with a Kramer passive wall plate insert or connector module for interfacing A/V type signals, if 
required. To install a wall-plate insert or connector module, do the following: 

1.  Unscrew the two screws that attach the blank plate 

to the connecting surface and remove the blank 
plate (save the two screws). 

 

2.  Place the required wall plate insert item over the 

opening.  

 

3.  Reinsert the two screws to affix the wall plate insert 

in position and tighten them. 

 

 

Installing the Power Socket 

To install the power socket: 

1.  Insert the modular power socket in its place (in this example, a universal power socket is 

shown, but you can use any of the available power sockets, see 

Power Socket 

Options

 on page 

5

). 

Summary of Contents for UTBUS-1XL

Page 1: ...P N 2900 300076 Rev 5 www kramerAV com USER MANUAL MODEL UTBUS 1xl Under the Table Connection Bus...

Page 2: ...ing the UTBUS 1xl Enclosure 4 Power Socket Options 5 Power Cord Options 5 Installing the UTBUS 1xl 6 Installing the Required Wall Plate Inserts 6 Installing the Power Socket 6 Installing the Cables 7...

Page 3: ...k if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables we recommend Kramer high performance high...

Page 4: ...ng it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment re...

Page 5: ...ting you install up to six wall plate inserts according to your requirements Has a power socket opening that is suitable for any of the following power sockets for the USA Germany the Europlug Belgium...

Page 6: ...Inserts on page 6 2 Power Socket Opening Suitable for international power requirements Suitable for international power requirements available with different types of power sockets ordered separately...

Page 7: ...5A Maximum 5A per power outlet Belgium and France TS 1FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel TS 1IL 80 001799 100 240V AC 50 60Hz 5A Maximum 5A per power outlet German...

Page 8: ...e can be removed and replaced with a Kramer passive wall plate insert or connector module for interfacing A V type signals if required To install a wall plate insert or connector module do the followi...

Page 9: ...t 2 Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure Securing the UTBUS 1xl Enclosure to the Table To install the UTBUS 1xl underneath the t...

Page 10: ...er outlet Belgium and France 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Switzerland 100 240V AC 50 60Hz 5A Maximum 5A 2 5A pe...

Page 11: ...y you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of...

Page 12: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...

Reviews: