background image

Kramer Electronics Ltd. 

 

UTBUS-1xl 

– Defining the UTBUS-1xl Enclosure 

 

Power Socket Options 

Inner frames support installing the following power socket assemblies. 

 

The Brazilian power sockets are supplied as dual power sockets in a single power socket 
assembly (see table below). 

Socket Type

 

Power Specs

 

Universal: 

 

TS-1U (80-000899) 

100-240V AC, 
50/60Hz, 5A 
Maximum 5A per 
power outlet 

Fully compatible

 with power plugs in the UK, India, Italy and 

Denmark, as well as with the 2-prong Europlug. 

Partially compatible

 (if the polarity is reversed) with plugs in 

China, Switzerland, Israel and the USA. The universal socket does 
not supply grounding to plugs in Central Europe and France and so 
you should order country specific sockets instead. 

Not compatible

 with South African plugs. 

 
 

Socket Type

 

Power Specs

 

Socket Type

 

Power Specs 

USA:

 

 

TS-1US (80-000999)

 

100-125V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

UK: 

 

TS-1UK (91-000022) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet

 

Belgium and France: 

 

TS-1FR (80-001399) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

Israel: 

 

TS-1IL (80-001799) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

Germany and EU: 

 

TS-1DE (80-001299) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

South Africa: 

 

TS-1ZA (80-001699) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet

 

Italy: 

 

TS-1IT (80-001499) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

Australia: 

 

TS-1AU (80-001599) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet 

Switzerland: 

 

TS-1CH (80-000027) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A per power outlet

 

Brazil: 

 

TS-BR (80-000034) 

100-240V AC, 50/60Hz, 5A 
Maximum 5A/2.5A per power 
outlet

 

Power Cord Options 

You can order any of the following power cords to use with a modular TBUS: 

Power Cord Type 

Description 

P/N 

6ft/110V (North America) 

C-AC/US (110V)  91-000099 

6ft/125V (Japan) 

C-AC/JP (125V) 

91-000699 

6ft/220V (Europe)  

C-AC/EU (220V)  91-000199 

6ft/220V (Israel) 

C-AC/IL (220V) 

91-000999 

6ft/250V (UK) 

C-AC/UK (250V)  91-000299 

6ft/250V (India)  

C-AC/IN (250V) 

91-001099 

6ft/250V/10A (China)  

C-AC/CN (250V)  91-001199 

6ft/250V/10A (South Africa)  C-AC/ZA (250V) 

91-001299 

 

Summary of Contents for UTBUS-1XL

Page 1: ...P N 2900 300076 Rev 5 www kramerAV com USER MANUAL MODEL UTBUS 1xl Under the Table Connection Bus...

Page 2: ...ing the UTBUS 1xl Enclosure 4 Power Socket Options 5 Power Cord Options 5 Installing the UTBUS 1xl 6 Installing the Required Wall Plate Inserts 6 Installing the Power Socket 6 Installing the Cables 7...

Page 3: ...k if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables we recommend Kramer high performance high...

Page 4: ...ng it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment re...

Page 5: ...ting you install up to six wall plate inserts according to your requirements Has a power socket opening that is suitable for any of the following power sockets for the USA Germany the Europlug Belgium...

Page 6: ...Inserts on page 6 2 Power Socket Opening Suitable for international power requirements Suitable for international power requirements available with different types of power sockets ordered separately...

Page 7: ...5A Maximum 5A per power outlet Belgium and France TS 1FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel TS 1IL 80 001799 100 240V AC 50 60Hz 5A Maximum 5A per power outlet German...

Page 8: ...e can be removed and replaced with a Kramer passive wall plate insert or connector module for interfacing A V type signals if required To install a wall plate insert or connector module do the followi...

Page 9: ...t 2 Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure Securing the UTBUS 1xl Enclosure to the Table To install the UTBUS 1xl underneath the t...

Page 10: ...er outlet Belgium and France 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Switzerland 100 240V AC 50 60Hz 5A Maximum 5A 2 5A pe...

Page 11: ...y you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of...

Page 12: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...