background image

 

18 

SL-14RC - Technical Specifications 

 

Technical Specifications 

SL-14RC

 

INPUTS: 

1 K-NET and 6 RS-232 on terminal block connectors 

1 Ethernet on RJ-45 connector 

1 infrared 

OUTPUTS: 

2 relays (36V AC or DC, 2A, 60VAC maximum on non-inductive load) 

1 GPI/O 

2 IR ports on terminal block connectors 

DEFAULT IP 

SETTINGS 

IP number 

 192.168.1.39; Mask – 255.255.0.0; Gateway – 0.0.0.0 

POWER SOURCE: 

100-240VAC 22VA 

OPERATING 

TEMPERATURE: 

0° to +55°C (32° to 131°F) 

STORAGE 

TEMPERATURE: 

-45° to +72°C (-49° to 162°F) 

HUMIDITY: 

10% to 90%, RHL non-condensing 

DIMENSIONS 

48.3cm x 11.5cm x 1U (19" x 4.5" x 1U) W, D, H (SL-14RC) 

8.9cm x 2.1cm x 2.3cm (3.5" x 0.8" x 0.9”) W, D, H (RC-3TB) 

WEIGHT: 

0.6kg (1.4lbs) approx. (SL-14RC) 

0.1kg (0.22lbs) approx. (RC-3TB) 

ACCESSORIES: 

Power cord, rack “ears” 

OPTIONS: 

RC-3TB Remote Control Panel, IR emitter cables 

Specifications are subject to change without notice  aRC-3TB 

 

DIMENSIONS 

8.9cm x 2.1cm x 2.3cm (3.5" x 0.8" x 0.9”) W, D, H 

WEIGHT: 

0.1kg (0.22lbs) approx. 

Summary of Contents for RC-3TB

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODELS SL 14RC Master Controller RC 3TB Remote Control Panel Optional P N 2900 000598 Rev 5...

Page 2: ......

Page 3: ...els Optional 12 7 Operating the SL 14RC 14 8 Front Panel Button Caps and Labels 15 8 1 Installing the Front Panel Button Caps and Labels 17 8 2 Replacing the Front Panel Button Labels 17 9 Technical S...

Page 4: ...defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Sp...

Page 5: ...com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance Use...

Page 6: ...ator LEDs configured using the K Config Configuration software 1 general purpose I O port that can be configured as an analog input digital input or digital output for interfacing with a variety of de...

Page 7: ...4 SL 14RC Overview 3 1 Defining the SL 14RC Master Controller This section defines the SL 14RC...

Page 8: ...tton Switches 1 10 Function is programmed by the K Config Configuration software 4 DISPLAY Configurable Button switches 11 and 12 Function is programmed by the K Config Configuration software 5 Rotary...

Page 9: ...he unit powers up and loads its memory with the factory default definitions and erases all stored presets 10 RS 232 Terminal Blocks Connect to the RS 232 devices from 1 to 6 11 RELAYS Terminal Blocks...

Page 10: ...igned to button 12 on SL 14RC 3 Buttons 2 and 3 Function is assigned by the rotary switch position 4 K NET Connector Connects to either SL 14RC or additional RC 3TB 5 8 Position Rotary Switch For assi...

Page 11: ...d by buttons 2 and 3 on the RC 3TB Rotary Switch Position Button 1 Button 2 Button 3 0 12 7 8 1 12 7 9 2 12 7 10 3 12 8 9 4 12 8 10 5 12 9 10 6 12 7 9 7 Service use only For example if the rotary swit...

Page 12: ...SL 14RC Installing in a Rack 9 5 Installing in a Rack This section provides instructions for rack mounting the unit...

Page 13: ...e screen 2 Connect the I O port to a motion detector 3 Connect the IR outputs as follows Connect an IR emitter to IR OUTPUT 1 and attach the emitter to the DVD player Connect an IR emitter to IR OUTPU...

Page 14: ...Controller 6 1 Connecting the RS 232 Interface To connect an AV device to the SL 14RC using the RS 232 port connect the RS 232 9 pin D sub port on your AV device to the RS 232 terminal block on the r...

Page 15: ...ith RJ 45 connectors 2 At the other end connect the Internet to a PC running Site CTRL 3 After connecting the Ethernet port you have to install and configure it For detailed instructions on how to ins...

Page 16: ...TB in the chain should be terminated 6 3 2 Daisy Chaining Multiple RC 3TB Remote Control Panels The wiring of two RC 3TB panels to the K NET port on the SL 14RC is shown in Figure 6 Connection of more...

Page 17: ...sing the K Config software For instructions on using the software see the K Config Software Guide available from our Web site at www kramerelectronics com RC 3TB Remote Control Panels optional A PC ru...

Page 18: ...Panel Button Caps and Labels 15 8 Front Panel Button Caps and Labels The SL 14RC is supplied with a button label sheet and 12 clear button caps to house the labels Figure 8 illustrates a sample butto...

Page 19: ...16 SL 14RC Front Panel Button Caps and Labels Figure 8 Sample Button Label Sheet...

Page 20: ...g the Front Panel Button Labels Note The button caps are a press fit on the buttons and must be removed carefully or the buttons may be damaged Remove the button caps only with the supplied button cap...

Page 21: ...00 240VAC 22VA OPERATING TEMPERATURE 0 to 55 C 32 to 131 F STORAGE TEMPERATURE 45 to 72 C 49 to 162 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 48 3cm x 11 5cm x 1U 19 x 4 5 x 1U W D H SL 14RC 8...

Page 22: ...t modification orfailure to follow instructions supplied withtheproduct iii Repair orattemptedrepairby anyone not authorized by Kramer iv Any shipment of theproduct claims must bepresentedtothe carrie...

Page 23: ...ributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Di...

Reviews: