SL-14RC - Connecting the SL-14RC
13
6.3.1
Terminating RC-3TB Remote Control Panels
If only one
RC-3TB
is connected, it must be terminated and the termination on the
SL-14RC
is turned off (see
Section 4
). When viewed from above and the rotary
switch is to the left of the termination switch, slide the termination switch to the left
as shown in
Only the last
RC-3TB
in the chain should be terminated.
6.3.2
Daisy-Chaining Multiple RC-3TB Remote Control Panels
The wiring of two
RC-3TB
panels to the
K-NET
port on the
SL-14RC
is shown in
. Connection of more than two
RC-3TB
panels follows the same principle.
Figure 7: Daisy-chaining Multiple RC-3TB Panels
Note the position of the termination switch on the first
RC-3TB
(open, to the right),
and that of the second
RC-3TB
(closed, to the left).
Connections to an
SL-14RC
or to another
RC-3TB
can be made to either
connector block as the connector blocks are functionally identical.