![background image](http://html1.mh-extra.com/html/kramer/rb-6/rb-6_user-manual_2001816032.webp)
28
RB-6 - RB-6 Communication Protocol
12
RB-6 Communication Protocol
The
RB-6
supports Kramer Protocol 3000.
Go to our Web site at
http://www.kramerelectronics.com
to check for
the latest
RB-6
communication protocol.
With Kramer Protocol 3000 you can control a device from any standard terminal
software (for example, the Windows
®
HyperTerminal Application).
This RS-232/RS-485 communications protocol uses a data rate of 115,200 baud,
no parity, 8 data bits and 1 stop bit.
12.1
Syntax
12.1.1
Host Message Format
Start
Address (optional)
Body
Delimiter
#
Destination_id@
Message
CR
12.1.1.1 Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP
Parameter_1,Parameter_2,…
CR
12.1.1.2 Command String
Formal syntax with commands concatenation and addressing:
Start
Address
Body
Delimiter
#
Destination_id@
Command_1
Parameter1_1,Parameter1_2,…|
Command_2
Parameter2_1,Parameter2_2,…|
Command_3
Parameter3_1,Parameter3_2,…|…
CR
12.1.2
Device Message Format
Start
Address (optional)
Body
delimiter
~
Sender_id@
Message
CR LF
i
im Vertrieb von CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203