background image

 

TBUS-3xl - Installing the TBUS-3xl 

 

5.1.1 

Mounting the Inserts 

You can rearrange or remove any of the plates mounted on the inner frame and 
replace them with Kramer passive wall plates or connector modules for interfacing 
A/V type signals. 

To mount a Kramer insert or connector module: 

1.  Unscrew the two screws that fasten the blank plate to the inner frame and 

remove the blank plate. 

2.  Place the required Kramer insert over the opening, insert the two screws to 

fix the Kramer insert in place, and tighten them. 

 

Figure 3: TBUS-3xl

 

Inner Frame (P/N: 80-003099) 

Feature 

Function 

Blank Plates 

Three blank covers that can be replaced with wall 

plates as required  

Adjustable Height Screw Holes  For adjusting the height of the Inner frame 

5.1.2 

Mounting the Power Socket Assemblies 

To mount the power socket, place the power socket under the frame in its 
appropriate place and tighten with the two screws (supplied). 

i

 

Power socket kits come with assembly instructions. 

Summary of Contents for MODULAR TBUS-3xl

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 3xl Table Connection Bus P N 2900 300062 Rev 2...

Page 2: ......

Page 3: ...TBUS 3xl through the Cut Out Opening 11 5 5 Connecting the Cables 12 5 6 Inserting Cables via the 4 cable Pass through Insert 12 5 7 Inserting the Pass through Cables 13 5 8 Adjusting the Height of th...

Page 4: ...hat are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repea...

Page 5: ...1 Achieving the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise l...

Page 6: ...ing for cable pass through note that other customized colors can also be ordered Height adjustment screw holes to set the inner frame ordered separately to the desired height Power socket openings tha...

Page 7: ...unit and ensure soft tightening to the table underside one for each clamp 5 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one for each clamp 6 Mounting Butterfly Screws Tighte...

Page 8: ...9 1 opening for 1 power socket 2 blank inserts 1 cable pass through insert T3F 1C P N 80 003199 1 opening for 1 power socket 4 cable pass through insert i Custom made inner frames can be designed if r...

Page 9: ...sed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not...

Page 10: ...pe Description P N 6ft 110V North America C AC US 110V 91 000099 6ft 125V Japan C AC JP 125V 91 000699 6ft 220V Europe C AC EU 220V 91 000199 6ft 220V Israel C AC IL 220V 91 000999 6ft 250V UK C AC UK...

Page 11: ...Section 5 4 5 Connect the cables see Section 5 5 6 Insert the cables via the 4 cable pass through insert see Section 5 6 7 Insert the cables via a pass through insert see Section 5 7 8 Adjust the hei...

Page 12: ...late 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 3xl Inner Frame P N 80 003099 Feature Function 1 Blank P...

Page 13: ...instructions 5 3 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 3xl on the surface of the table exactly where you...

Page 14: ...d from around the outer rim of the TBUS 3xl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 5 3 Take the support brackets under the table and place th...

Page 15: ...s via the 4 cable pass through insert for example to pass cables from beneath the table to several laptops do the following 1 Remove the four screws attaching the split pass through bracket 2 Remove t...

Page 16: ...h bracket 2 Remove the split grommet 3 Insert the cable through the rectangular opening 4 Open the split grommet slightly and insert the required cables 5 Place the split bracket around the grommet an...

Page 17: ...djust the inner frame height to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers 2...

Page 18: ...Using the TBUS 3xl Once the TBUS 3xl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 7 Figure 7...

Page 19: ...France 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel 220V AC 50 60Hz...