background image

 

TBUS-3xl - Your TBUS-3xl Enclosure 

 

4.1  TBUS-3xl Optional Inner Frames 

The following inner frames can be installed in the 

TBUS-3xl

 enclosure: 

Inner Frames for TBUS-3xl 

Specifications (define what you can include in this 

inner frame): 

 

T3F-1S (P/N: 80-002999) 

 

1 opening for 1 power socket 

1 USB connector 

1 VGA 15-pin HD connector 

1 RJ-45 Ethernet connector 

A 3.5mm mini jack AUDIO connector 

 

T3F-13 (P/N: 80-003099) 

 

1 opening for 1 power socket 

2 blank inserts 

1 cable pass-through insert 

 

 

 

T3F-1C (P/N: 80-003199) 

 

1 opening for 1 power socket 

4-cable pass-through insert  

 
 

 

i

 

Custom made inner frames can be designed if required. 
Contact Kramer Electronics for more details. 

4.2  TBUS-3xl Accessories 

Accessories 

Description 

Inserts 

You can install any wall plate devices as well as any of 

the single or dual inserts—see our Web site for details.  

 

T-2INSERT (P/N: 80-00006699) 

 

The 

T-2INSERT

 kit can be installed inside a single 

power socket opening and includes: 

 

1 single cable pass-through insert  

1 dual cable pass-through insert 

Summary of Contents for MODULAR TBUS-3xl

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 3xl Table Connection Bus P N 2900 300062 Rev 2...

Page 2: ......

Page 3: ...TBUS 3xl through the Cut Out Opening 11 5 5 Connecting the Cables 12 5 6 Inserting Cables via the 4 cable Pass through Insert 12 5 7 Inserting the Pass through Cables 13 5 8 Adjusting the Height of th...

Page 4: ...hat are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repea...

Page 5: ...1 Achieving the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise l...

Page 6: ...ing for cable pass through note that other customized colors can also be ordered Height adjustment screw holes to set the inner frame ordered separately to the desired height Power socket openings tha...

Page 7: ...unit and ensure soft tightening to the table underside one for each clamp 5 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one for each clamp 6 Mounting Butterfly Screws Tighte...

Page 8: ...9 1 opening for 1 power socket 2 blank inserts 1 cable pass through insert T3F 1C P N 80 003199 1 opening for 1 power socket 4 cable pass through insert i Custom made inner frames can be designed if r...

Page 9: ...sed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not...

Page 10: ...pe Description P N 6ft 110V North America C AC US 110V 91 000099 6ft 125V Japan C AC JP 125V 91 000699 6ft 220V Europe C AC EU 220V 91 000199 6ft 220V Israel C AC IL 220V 91 000999 6ft 250V UK C AC UK...

Page 11: ...Section 5 4 5 Connect the cables see Section 5 5 6 Insert the cables via the 4 cable pass through insert see Section 5 6 7 Insert the cables via a pass through insert see Section 5 7 8 Adjust the hei...

Page 12: ...late 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 3xl Inner Frame P N 80 003099 Feature Function 1 Blank P...

Page 13: ...instructions 5 3 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 3xl on the surface of the table exactly where you...

Page 14: ...d from around the outer rim of the TBUS 3xl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 5 3 Take the support brackets under the table and place th...

Page 15: ...s via the 4 cable pass through insert for example to pass cables from beneath the table to several laptops do the following 1 Remove the four screws attaching the split pass through bracket 2 Remove t...

Page 16: ...h bracket 2 Remove the split grommet 3 Insert the cable through the rectangular opening 4 Open the split grommet slightly and insert the required cables 5 Place the split bracket around the grommet an...

Page 17: ...djust the inner frame height to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers 2...

Page 18: ...Using the TBUS 3xl Once the TBUS 3xl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 7 Figure 7...

Page 19: ...France 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel 220V AC 50 60Hz...

Page 20: ...TBUS 3xl 17...

Page 21: ......

Page 22: ...ributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site E mail www kramerelectronics com info kramerel com SAFETY WARNING Di...

Reviews: