![background image](http://html1.mh-extra.com/html/kramer/fc-7p/fc-7p_user-manual_2001014046.webp)
Kramer Electronics Ltd.
FC-7P
– Kramer Protocol 3000
44
MACH-NUM
Functions
Permission
Transparency
Set:
MACH-NUM
End User
Public
Get:
-
-
Description
Syntax
Set:
Set machine number (device ID)
#MACH-NUMSP
machine_number
CR
Get:
-
-
Response
~nn@MACH-NUMSP
machine_number
CR LF
Parameters
machine_number
– New machine number
Response Triggers
Notes
The new machine number is only set after restarting the device.
K-Config Example
“#MACH
-
NUM 4”,0x0D
MODEL
Functions
Permission
Transparency
Set:
-
-
-
Get:
MODEL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#MODEL?CR
Response
~nn@MODELSP
model_name
CR LF
Parameters
model_name
– String of up to 19 printable ASCII chars
Response Triggers
Notes
This command identifies equipment connected to Step-in master products and notifies of identity changes
to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
K-Config Example
“#MODEL?”,0x0D