Kramer Electronics Ltd.
FC-7P
– Kramer Protocol 3000
37
ETH-PORT
Functions
Permission
Transparency
Set:
ETH-PORT
Administrator
Public
Get:
ETH-PORT?
End User
Public
Description
Syntax
Set:
Set Ethernet port protocol
#ETH-PORTSP
portType,ETHPort
CR
Get:
Get Ethernet port protocol
#ETH-PORT?SP
portType
CR
Response
~nn@ETH-PORTSP
portType,ETHPort
CR LF
Parameters
portType
–
1
(UDP),
2
(TCP)
ETHPort
– TCP/UDP port number
Response Triggers
K-Config Example
Set ETH port 1 to UDP.
“ETH
-
PORT 2,1”,0x0D
ETH-TUNNEL
Functions
Permission
Transparency
Set:
-
-
-
Get:
ETH-TUNNEL?
Administrator
Internal
Description
Syntax
Set:
Get:
Get parameters for an open tunnel
#ETH-TUNNEL?
␠
TunnelId
␍
Response
~nn@ETH-TUNNEL
␠
TunnelId,ComNum,PortType,EthPort,EthIp,RemotPort,EthRepEn,Wired
␍␊
Parameters
TunnelId
– tunnel ID number:
1-64
(depends on number of tunnel connections),
*
(all tunnel
connections)
ComNum
– UART number
portType
–
1
(UDP),
2
(TCP)
ETHPort
– TCP/UDP port number
EthIp
– client IP address
RemotPort
– remote port number
EthRepEn
–
1
(COM port sends replies to new clients),
0
(COM port does not send replies to new clients)
Wired
–
1
(wired connection),
0
(not wired connection)
Response Triggers
Notes
The response displays each tunnel in a separate line.
K-Config Example
“ETH
-