30
OIE 12en Edition 2019-02
Operating Instructions
Operation at a glance
O
p
e
ra
ti
o
n
o
f
th
e
b
a
s
ic
f
u
n
c
ti
o
n
s
Operating the basic functions
The following table describes the basic operating steps. They can be carried out in part without a
password having to be entered.
Tab. 3 Operating the basic functions
Aim
Operating steps
Reading the consumption
see "1.01 Consumption",
Page 34
►
Press ARROW UP and ARROW DOWN simultaneously.
"Consumption " is displayed.
Resetting totals
see "1.02 Total with reset",
Page 34,
see "1.04 Volumeter A Total
with reset", Page 35 or
see "1.06 Volumeter B Total
with reset", Page 35
1. Select menu 1.02, 1.04 or 1.06.
2. Press SET.
Total 1 flashes.
3. Press SET for 3 seconds.
Total 1 is set to 0.
4. Press SET.
Total 2 flashes.
5. Press SET for 3 seconds.
The password prompt is displayed.
6. Enter the password and press SET.
Total 2 is reset.
Select the language
see "1.13 Setting select
language", Page 34
1. Press SET and ARROW RIGHT simultaneously.
"Language selection" is displayed.
2. Press SET.
3. Press ARROW DOWN/ARROW UP to select the language.
4. Press SET.
The language is selected.
After you have navigated to a different page, the language is
used in the display.
Calling up help
1. Press ARROW RIGHT and ARROW LEFT simultaneously.
Information about the operation is displayed.
2. Scroll using ARROW UP/ARROW DOWN.
3. Use SET to exit the page.
Checking the selection
of the density table
see "2.09 Select density
determination", Page 38
1. Press ARROW LEFT/ARROW RIGHT to access menu 2.
2. Use ARROW UP/ARROW DOWN to scroll to Page 2.08.
The selected density table is displayed.
Checking the values
of a density table
see "Menu 6: Density table 1/
Density determination",
Page 44 or
see "Menu 7: Density table
2", Page 45
1. Press ARROW LEFT/ARROW RIGHT to access menu 6 or 7.
2. Use ARROW UP/ARROW DOWN to select the desired page of the
density table.
The density or temperature value is displayed.
Checking the values
for the K-factors
see "Menu 4: K-factors
Volumeter A", Page 44 or
see "Menu 5: K-factors
Volumeter B", Page 44
1. Press ARROW RIGHT/ARROW LEFT in order to access menu 4
"K-factors Volumeter A".
2. Use ARROW UP/ARROW DOWN to select the pages of the
individual K-factors Volumeter A.
3. Check the K-factors Volumeter A.
4. Press ARROW RIGHT/ARROW LEFT in order to access menu 5
"K-factors Volumeter B".
5. Check the K-factors Volumeter B.