ADJUSTMENT
43
12.2.2 Vent Restriction
WARNING: To avoid property damage or personal injury, allow
the fireplace ample time to cool before making any adjustments.
WARNING: Improper vent installation may cause the burner
flames to lift or “ghost.” Perform a visual check on flame
appearance after restrictor adjustment to ensure proper
performance.
Vertical terminations may display an active, compact flame.
To achieve desirable flame appearance, the vent exit may be
restricted by the restrictor plate (included in components packet).
This fireplace is shipped with the restrictor located in the fireplace
baffle set in the open position. Follow the tables below to adjust
the restrictor to desired flame appearance. Allow the fireplace
to burn for 15 minutes before making any adjustments to the
restrictor setting.
Table 12.5, Restrictor Adjustment for Flame Appearance
Flame
Appearance
Draft Problem
Vent Restriction
Short, flickering
Excessive draft
Not enough
restriction
Close baffle restrictor
Install restrictor plate
Lifting or ghosting* Insufficient draft
Too much
restriction
Open baffle restrictor
Remove inner ring(s) on
restrictor plate, or remove
restrictor plate
*If flames continue to lift or ghost after opening the baffle restrictor or
installing and verifying correct vent installation, shut off the gas supply
and call a qualified service technician.
12.2.2.1 Restrictor Plate Installation
1. Remove the safety barrier and the glass frame assembly.
2. Remove (2) screws securing termination access panel.
Release panel tabs from slots in baffle.
3. Bend the tabs on the restrictor plate (included in components
packet) to approximately 80° angles. This will create tension
when the restrictor is inserted into the exhaust pipe.
4. Insert restrictor into the 5 in (127 mm) exhaust pipe with the
tabs pointing towards you.
5. Reinstall termination access panel by inserting tabs in
panel into slots in baffle. Secure with (2) screws previously
removed.
6. Reinstall all components previously removed.
12.2.2.2 Restrictor Plate Modification
1. Remove the safety barrier and the glass frame assembly.
2. Remove (2) screws securing termination access panel.
Release panel tabs from slots in baffle.
3. Remove the restrictor by pulling it down and out of the 5 in
(127 mm) exhaust pipe.
4. Make necessary modifications to achieve desired flame
appearance.
5. Insert restrictor into the 5 in (127 mm) exhaust pipe with the
tabs pointing towards you.
6. Reinstall termination access panel by inserting tabs in
panel into slots in baffle. Secure with (2) screws previously
removed.
7. Reinstall all components previously removed.
RESTRICTOR PLATE
BEND TABS TO APPROX. 80° ANGLES TO CREATE
TENSION TO HOLD ITSELF IN PLACE WHEN INSTALLED
REMOVE CIRCLE TO
CREATE LESS RESTRICTON
Figure 12.4, Restrictor Installation and Modification
(2) SCREWS SECURING
TERMINATION ACCESS PANEL