20
FACING AND FINISHING
5.2 Facing Requirements
WARNING: Maintain all minimum clearances to combustibles
from the appliance and vent system.
• Non-combustible material is required at the top and sides of
the fireplace.
• This fireplace is designed to accommodate non-combustible
facing material up to ½ in (13mm) thick.
• Install facing material up to the finishing edge that surrounds
the glass frame assembly. Do not apply any material beyond
this point. The glass frame assembly must be removable.
• Do not secure material to the lower cover panel using
screws. This may damage control system components.
To secure material in this zone, use a silicone sealant that
has a 300°F (149°C) continuous exposure rating.
• It is acceptable to pre-drill holes and to use self-tapping
screws to attach non-combustible material to the top and
sides of the fireplace face. Do not use excessively long
screws.
62
¼
”
(1581mm)
4
¾
”
(121mm)
10
¾
”
(274mm)
17
15⁄16
”
(456mm)
8
1⁄8
”
(206mm)
71
7⁄8
”
(1807mm)
36
7⁄8
”
(936mm)
61
3⁄8
”
(1560mm)
Figure 5.2, Finished Opening Clearances
NON-COMBUSTIBLE MATERIAL ONLY
COMBUSTIBLE MATERIAL ALLOWED
COMBUSTIBLE MATERIAL ALLOWED
LOWER COVER PANEL
COMBUSTIBLE MATERIAL ALLOWED
NO SCREWS ABOVE FRAMING
(BOTTOM
¾
” [19mm])
63”
(1600mm)
11
½
”
(292mm)
¾
”
(19mm)
5
½
”
(140mm)
8
7⁄8
”
(225mm)
61
7⁄16
”
(1561mm)
5
½
”
(140mm)
¾
”
(19mm)
¾
”
(19mm)
17
15⁄16
”
(456mm)
¾
”
(19mm)
72
5⁄8
”
(1845mm)
38
3⁄8
”
(975mm)
COMBUSTIBLE MATERIAL
ALLOWED
NON-COMBUSTIBLE MATERIAL ONLY
Figure 5.3, Minimum Non-Combustible Material Dimensions