Page 4
Pellet Setting
Auger LED Light
ON/OFF LED Light
Corn Setting
#5
#4
#3
#2
#1
CIRCUIT CONTROL BOARD
CIRCUIT CONTROL BOARD FUNCTIONS:
A. ON/OFF:
This button turns the circuit control
board ‘ON’ and ‘OFF’. This button is also used to
‘reset’ the board after it has switched to Diagnostic
mode.
B. HEAT LEVEL: This button advances the heat settings
between level #1 and level #5. If level #5 is
selected and the button is depressed again, the
setting will change to level #1. The ‘LED’ light will
indicate which heat setting is active.
C. AUGER: The Auger will not start operating for 4 ½
minutes after the control circuit board has been
turned on. If the auger is empty, it will take 3 to 4
minutes for fuel to start dropping into the burn pot.
The AUGER button allows you to manually auger
fuel into the burn pot on start up, if needed.
D. FAN:
The fan button will adjust the ‘convection’
fan on heat setting level 1 only. Push the button
and the red LED light will flash once to decrease
the voltage 5 volts. Pushing the button again will
cause the LED light to flash twice and decreases
the fan voltage another 5 volts. If the button is
pushed a third time, the voltage will reset to the
normal setting.
E. AUGER TRIM : The auger trim button allows the
feed rate to be adjusted on heat setting level #1
only and may be set to #1 Normal, #1 High, and
#1 Low. LED lights on the control board indicates
which auger trim level is active.
1. Normal - The first LED light indicates that it set
at the ‘Normal’ setting. The auger ‘ON’ time is
2.00 seconds.
2. High - Pressing the auger trim button once
changes it to ‘High’. The first & fourth LED lights
are on. The auger ‘ON’ time is 2.40 seconds.
3. Low - Pressing the auger trim button twice
changes it to ‘Low’. The first & third LED lights
are on. The auger ‘ON’ time is 1.40 seconds.