VENTING
NOTE: Horizontal sections require 1/4” (6 mm) rise for every
12” (305 mm) of travel.
NOTE: Horizontal Vent Heat Shield not used in corner installations.
HORIZONTAL TERMINATIONS
TYPICAL CORNER INSTALLATION
45° elbow + 90
˚
elbow + horizontal pipe + termination cap.
PAGE 24
90° ELBOW
Vent Opening Dimensions: Refer to vent pipe manufacturer's instructions.
VENTING DIMENSIONS FOR MINIMUM
CORNER INSTALLATIONS
HORIZONTAL
TERMINATION CAP
NOTE: Page 26 has information on restrictor installation in conjunction with venting installation. Page 51 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
CAUTION: This gas appliance must not be connected to or joined
with any other chimney flue serving another appliance.
PIPE
45° ELBOW
IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.
Exception: corner installations
Kozy Heat Wall Pass-thru, #800-WPT (4-1/2” (114 mm) - 6-1/2” (165 mm) wall thickness) or #800-WPT2 (6-1/2” (165 mm) - 12-1/2” (318 mm) wall
thickness), must be used on all horizontal vent runs.