55345-RF
NATURAL GAS
LP GAS
MINIMUM INLET GAS PRESSURE
5.0 inches W.C. (7.0 W.C. recommended)
11.0 inches W.C. (recommended)
MAXIMUM INLET GAS PRESSURE
10.5 inches W.C.
13.0 inches W.C.
MANIFOLD PRESSURE (HI)
3.5 inches W.C
10.0 inches W.C.
MANIFOLD PRESSURE (LO)
1.7 inches W.C.
6.3 inches W.C
ORIFICE SIZE
#55 & #34
#68 & #51
INPUT BTU/hr.
40,000
40,000
MINIMUM INPUT BTU/hr.
21,500
26,500
EFFICIENCY
69%
73%
AFUE
68%
72%
P-4 AFE
66%
63%
55345
NATURAL GAS
LP GAS
MINIMUM INLET GAS PRESSURE
5.0 inches W.C. (7.0 W.C. recommended)
11.0 inches W.C. (recommended)
MAXIMUM INLET GAS PRESSURE
10.5 inches W.C.
13.0 inches W.C.
MANIFOLD PRESSURE (HI)
3.8 inches W.C
10.0 inches W.C.
MANIFOLD PRESSURE (LO)
1.1 inches W.C.
6.3 inches W.C
ORIFICE SIZE
#55 "
#68 & #51
INPUT BTU/hr.
40,000
40,000
MINIMUM INPUT BTU/hr.
21,500
26,500
EFFICIENCY
69%
73%
AFUE
68%
72%
P-4 AFE
66%
63%
GAS LINE CONNECTION