22
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Kozy Power Vent #KPV
Issue
Cause
Solution
Pilot and burner
extinguish while in
operation
No propane in tank
Check propane tank. Refill if necessary.
Incorrect glass assembly
installation
Adjust if necessary. See appliance installation manual.
Incorrect vent cap installation
Adjust if necessary.
Vent cap blockage
Remove debris if necessary.
Exhaust vent pipe leaking
exhaust gases back into firebox
Check for leaks and repair if necessary.
Excessive draft
Adjust the draft bypass system. Refer to Section 2.3 Draft Bypass
Soot appears on glass
Improper media placement
See appliance installation manual.
Improper venturi setting
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix.
Incorrect vent cap installation
Adjust if necessary.
Vent cap blockage
Remove debris if necessary.
Flame burns blue and lifts
off burner
Improper venturi setting
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix. See appliance installation manual.
Incorrect vent cap installation
Adjust if necessary.
Blockage or leakage of the vent
system
Check the vent pipes for leaks, and the vent cap for debris. Repair the vent
pipes or remove debris from vent cap, if necessary.
Excessive draft
Adjust the draft bypass system. Refer to Section 2.3 Draft Bypass
No reaction to command
No communication between
remote control and IFC module
Reprogram remote control to IFC module. See appliance installation
manual.
A maximum number of failed
ignitions or flame restorations
has been reached
Reset IFC module. See appliance installation manual.