28
FIREPLACE SETUP
8.5 Control Board Removal
and Installation
WARNING: If burner and/or pilot have been burning,
use appropriate protection to avoid burns or damage
to personal property before removing any components.
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING
GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water,
whether field or factory made.
8.5.1 Control Board Removal
1. Disconnect electrical power.
2. Locate the manual valve installed by your qualified service
technician.
3. Turn the manual valve clockwise to the OFF position.
4. Remove the safety barrier and glass frame assembly.
5. Remove glass media and media tray.
6. Remove burner cover from firebox (8) screws.
7. Remove burner tube from firebox floor (3) screws.
8. Remove halogen bulbs. Loosen (4) screws that secure light
brackets to control board.
9. Pull light bracket assemblies away from control board,
allowing access to screws securing control board to firebox
bottom.
10. Remove and save (8) screws securing control board to
firebox bottom.
11. Lift control board out of firebox, being careful not to damage
sealing gasket lying underneath.
8.5.2 Control Board Installation
1. Place the control board in firebox, aligning the holes in board
with mounting studs at the bottom of the firebox.
VERIFY SEALING GASKET IS IN PLACE.
2. Secure the control board with screws previously removed.
3. Re-attach light brackets, tighten screws. Reinstall halogen
bulbs.
4. Reinstall burner tube, positioning burner venturi over burner
orifice. Align the mounting holes with the corresponding
holes in the control board and secure with (3) screws
previously removed.
5. Reinstall burner cover, aligning holes in cover to
corresponding holes on burner. Secure with (8) screws
previously removed.
6. Reinstall glass media, being careful not to block pilot.
7. Reconnect all wiring harnesses to gas valve. Plug all
components into electrical outlet.
8. Reinstall glass assembly and safety barrier.
9. Turn the manual valve counterclockwise to the ON position.
10. Reconnect electrical power.
11. Verify proper glass media placement, operation of fireplace,
and any electrical components.
Figure 8.5, Control Board Removal and Installation