background image

16

  FACING AND FINISHING

4.2  Mantel Requirements

Figure 4.2, Mantel, Trim and Sidewall Requirements

SIDEWALL CLEARANCE

14”

(356mm)

22”

(559mm)

16”

(406mm)

¾

(19mm)

10”

(254mm)

4”

(102mm)

13

½

(344mm)

½

” (13mm) NON-COMBUSTIBLE

MATERIAL ONLY

NON-COMBUSTIBLE ZONE

Summary of Contents for DELANO-36S

Page 1: ...me where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified k...

Page 2: ......

Page 3: ...safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeowner...

Page 4: ......

Page 5: ...rements 20 7 3 Use of Elbows 20 7 4 Restrictor Assembly and Installation 20 7 5 Vertical Terminations 21 7 6 Combination Venting 22 7 7 800 1 Series Direct Vent Termination Kit s 24 7 8 Horizontal Ven...

Page 6: ......

Page 7: ...he above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the bu...

Page 8: ...WC 0 95 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 0 72 kPa Orifice Size DMS 42 54 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer to N...

Page 9: ...Frame Height Stand off Height Back to Vent Center Inches 32 35 7 8 27 7 8 15 1 4 31 3 8 24 10 7 1 2 Millimeters 813 912 708 387 797 609 254 190 Figure 2 1 Delano 36S Unit Dimensions 15 387mm 277 8 708...

Page 10: ...d with the appliance shall be used 2 4 1 Safety Barrier Installation 1 Center the screen front over the glass frame assembly allowing the screen front s mounting brackets to fit inside the air opening...

Page 11: ...to the header Use only non combustible material in this area for the entire width of the fireplace DO NOT use wood sheetrock et cetera in this zone Top stand off brackets must be formed and attached...

Page 12: ...o ceiling 31 in 787 mm Appliance sides to adjacent sidewall 1 1 2 in 38 mm From appliance front 36 in 914 mm Top of appliance to 3 4 in 19mm trim 10 in 254 mm Mantel 4 in 102 mm deep from appliance to...

Page 13: ...and fireplace facing materials If using a hearth adjust the rough opening size as necessary to maintain minimum clearance requirements If masonry is to be used optional prepare the necessary foundatio...

Page 14: ...nstructed in compliance with local building codes Outside walls should be insulated to prevent cold air from entering room Follow vent pipe manufacturer s installation instructions for vertical termin...

Page 15: ...flanges on the nailing flanges facing away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flan...

Page 16: ...INISHING 4 2 Mantel Requirements Figure 4 2 Mantel Trim and Sidewall Requirements SIDEWALL CLEARANCE 14 356mm 22 559mm 16 406mm 19mm 10 254mm 4 102mm 13 344mm 13mm NON COMBUSTIBLE MATERIAL ONLY NON CO...

Page 17: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Page 18: ...er 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27...

Page 19: ...air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Clearance abo...

Page 20: ...all Pass Through NOTE If using a vent 4 x 6 5 8 Decreaser follow the vent pipe manufacturer s wall thimble installation instructions Kozy Heat s 800 WPT series or wall thimble products that comply wit...

Page 21: ...tical Length Maximum Vertical Length 4 ft 1219 mm 50 ft 15 2 m 7 5 2 4 x 65 8 Reducer Vent Configurations Table 7 4 NG LPG Minimum Maximum Vertical Terminations Minimum 5 x 8 Vertical Length Minimum 4...

Page 22: ...un 90 elbow 6 in 152 mm 25 ft 7 6 m 90 elbow 6 in 152 mm 30 ft 9 14 m Horizontal terminations over 25 ft 7 6 m must use stainless steel pipe for entire length of vent system Table 7 6 NG LPG Max Verti...

Page 23: ...tions over 25 ft 7 6 m must use stainless steel pipe for entire length of vent system Table 7 8 NG LPG Max Vertical Max Horizontal Combination Maximum Vertical Rise Maximum Horizontal Run Total Length...

Page 24: ...sealant around outer edge of termination box A placing assembly through the wall pass through in exterior wall Place screws through the four holes B securing it in place 4 Form the 5 8 flexible alumi...

Page 25: ...ntal venting 1 Loosen but do not remove the 3 attachment screws in front of the flue collar on the top of the fireplace 2 Bend the heat shield at perforation to a 90 angle 3 Slide the 2 slots on horiz...

Page 26: ...touch with bare hands Always use a soft cloth when handling 1 Remove 8 screws securing burner cover then lift the cover out of the firebox 2 Loosen but do not remove 4 screws securing light bars to f...

Page 27: ...o working on any electrical lines NOTE It easier to install the fan kit before connecting the gas line to the control board This appliance when installed must be electrically grounded in accordance wi...

Page 28: ...ttom 10 Remove and save 8 screws securing control board to firebox bottom 11 Lift control board out of firebox being careful not to damage sealing gasket lying underneath 8 5 2 Control Board Installat...

Page 29: ...t or remove the grounding prong from this plug 9 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes...

Page 30: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Page 31: ...osition for remote control operation of the main burner and fireplace features 10 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Page 32: ...imately 2 seconds move the switch to the ON position The ignition sequence will start again 10 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After appr...

Page 33: ...standing pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LC...

Page 34: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Page 35: ...ode Fan s will operate at previous setting There is no delay in start up or stop time 10 8 9 Accent Light Kit The light intensity can be adjusted through 6 levels 1 Press the mode key to index to the...

Page 36: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Page 37: ...ame that may lift off the burner Table 11 3 Factory Set Venturi Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 15 mm OPEN 11 2 1 1 Venturi Adjustment 1 Remove safety barrier gl...

Page 38: ...s frame assembly 2 Remove 2 screws securing termination access panel located on the fireplace baffle 3 Bend the tabs on the restrictor included in fireplace components packet to approximately 80 angle...

Page 39: ...LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Page 40: ...26 Improper venturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 11 2 1 Burner Venturi on page 37 Incorrect vent cap installation Adju...

Page 41: ...ir intake system is disassembled for any reason reinstall per instructions provided with installation Refer to Section 7 0 Venting on page 20 Performed by Qualified Service Person Frequency Annually A...

Page 42: ...er Orifice 42 700 242 IFC Wire Harness Assembly 700 653 LPG Burner Orifice 54 700 254 Pilot Assembly NG 700 551 Conversion Kit NG NCK DEL S Pilot Assembly LPG 700 551 1 Conversion Kit LPG LCK DEL S Tr...

Page 43: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Page 44: ......

Page 45: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Reviews: