5.4 Kozy Heat #816-CL Co-Linear Vent
System
IMPORTANT: Proper operation of this insert requires the
exhaust and combustion air pipes to be connected to the
correct collar, on both the termination kit and the fireplace
insert air duct.
5.4.1 Full Connection Venting Assembly
1. Carefully extend the exhaust and combustion air intake
pipes to the total chimney length required. Refer to 3.2.1,
Determine Existing Chimney Length, on page 9.
2. Slide the combustion air intake pipe (the end without a
collar) over the intake termination cap collar (A).
3. Secure the combustion air intake pipe to the termination cap
(E) with the provided (3) self-tapping screws (D).
4. Place a bead of sealant around the inner edge at the end of
the exhaust pipe (without collar / red marking).
5. Slide the exhaust pipe onto corresponding labeled collar (B)
on the termination cap (E).
6. Secure the exhaust pipe to the termination cap (E) with the
provided (3) self-tapping screws. Apply additional sealant
around joint to ensure a proper seal (C
1
).
7. Run vent system. Refer to 5.5.1 Run Vent - Full Connection
Venting, on page 14.
5.4.2 Stub Venting Assembly
1. Determine the length needed for the combustion air intake
pipe, measuring from the fireplace air duct to above to a
minimum length of 4 ft. (1.22 m) above the damper opening
in the existing chimney.
2. Remove the excess length of combustion air pipe (from the
end without a collar).
3. Extend the exhaust pipe equal to the total chimney length
required. Refer to 3.2.1 Determine Length of Existing
Chimney, on page 10.
4. Place a bead of sealant around the inner edge at the end of
the exhaust pipe (without collar / red marking).
5. Slide the exhaust pipe onto corresponding labeled collar (B)
on the termination cap (E).
6. Secure the exhaust pipe to the termination cap (E) with the
provided (3) self-tapping screws. Apply additional sealant
around joint to ensure a proper seal (C
1
).
7. Run vent system through existing chimney. Refer to
5.5.2 Run Vent - Stub Venting, on page 14.
D
A
C
2
C
1
B
IMPORTANT: The exhaust collar on the fireplace insert air duct
is on the right side. Install the #816-CL termination cap (E) with
the exhaust collar on the right side. The exhaust pipe will have
a red marking.
LEGEND
A
Intake Collar - extends through bottom plate
B
Exhaust Collar - extends through middle divider plate
C
1
-C
2
Sealant
D
Self-Tapping Screws - (3) total (2 shown)
E
Termination Cap
Figure 5.2, #816-CL Termination Cap (your component may look different than the one shown)
13