21
8.3 CK34-LKT Optional Light Kit
Installation
ATTENTION: If converting to LP (propane) gas, complete the
conversion before installing this light kit. Follow instructions
included with the gas conversion kit.
CAUTION: Disconnect all electric power from the fireplace
insert before performing any of these tasks.
NOTE: To avoid damage and prolong the life of the halogen
bulbs, never touch with bare hands. Always use a soft cloth
when handling.
Remove the following items from the fireplace insert:
• Safety barrier and glass frame assembly
• Log set or rock set
• Refractory panels (if installed)
• Ember panel
• Burner assembly
1. Remove the first access cover held by (2) screws.
2. Remove the secondary heat shield.
3. Remove and save the (1) screw securing the second access
cover. Secure control board underneath using previously
removed screw.
4. Install the rubber grommet then thread the lead wires on the
light bar through the grommet.
5. Connect the light wires to the light lead wires on the IFC
module. Apply high temperature sealant around the grommet
and wires to create an air-tight seal.
6. Install (4) halogen bulbs into the lamp bases. Check bulbs
turning the lights on by remote control. Unplug the IFC
module before continuing.
7. Reinstall the secondary heat shield.
8. Reinstall the burner assembly previously removed.
9. Reinstall the refractory panels (if used) and the ember panel.
10. Place glass media into the cavity in front of the burner
assembly.
11. Reinstall log set or rock set. Use a steel bristle or stiff bristle
brush to distribute rock wool embers onto the logs and
burner.
12. Reinstall the glass frame assembly and the safety barrier.
First Access Cover
Second Access
Cover
Figure 8.2, CK34-LKT Installation
Summary of Contents for Chaska-34 LOG