FACING AND FINISHING
8.2 Shroud Installation
CAUTION: Trim panels or surrounds must not seal ventilation
openings in existing fireplace that this appliance is installed in.
WARNING: The flow of combustion and ventilation air must not
be obstructed.
For shrouds #CK29-2538, #CK29-27542, #CK29-3044,
#CK29A-2838, #CK29-CUS and #CK29-ACUS.
1.
Remove the upper hood by lifting up and out of the mounting
langes.
2.
Remove lower louver by lifting the louver out of the slots on
the mounting bracket.
3.
Remove the glass assembly.
4.
Align the mounting holes on the shroud to the corresponding
mounting nuts on the sides of the insert metal cabinet.
5.
Secure with (4) truss head screws (provided).
6.
Reinstall all components previously removed.
Figure 8.2, Upper Hood Removal
Figure 8.3, Lower Louver Removal
8.3 Safety Barrier Installation
For safety barriers CK29-BSF, CK29-CXF, CK29-PSF, CK29-
RSF, CK29A-MSF, CK29A-SF, CK29A-PSF, and CK29A-FPDSF.
1.
Locate the (4) slots on the shroud (2 each side).
2.
Align the tabs located on the back of the safety barrier with
the slots on the shroud.
3.
Raise the safety barrier slightly into the slots and allow the
tabs to lower into position.
•
To remove safety screen: lift the screen up and out of slots.
MOUNTING
NUTS
(2 EACH SIDE)
Figure 8.4, Mounting Nuts Location