Safety Barrier Installation
SECTION 4
FACING AND FINISHING
#CAR-39
R.11 February 2022
29
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
4.3.2 Overlap Fit - Hanging Installation with
Adjustable Louvers (Open Bracket)
Model #C39A-FPDSF2
The listed safety barriers are equipped with the louver built into the
safety screen face. The hanging brackets located on the back of screen
front are equipped with (2) notched brackets to allow the louver to be
adjusted to accommodate facing material thickness. The safety barrier
is shipped with the louver in the first notch position.
To adjust louver position:
1. Locate the (2) louver brackets at the bottom of the safety screen.
One of the louvers bracket end is open at the top to allow
removal and adjustment of the louver depending on the safety
barrier position for installation and facing material thickness.
2. Slide the louver up and out on the open bracket end and pull it
out of the closed bracket end.
3. Adjust the louver to the desired notch in order to accommodate
facing material and to cover the control compartment as
you see fit.
NOTE: The position of the louver should match with the desired
position of the notched tabs needed for your installation. The louver
in the first notch position will match with the first notch position in
the notched tabs, the louver in the second notch position will match
the second notch in the notched tabs, etc.
4. Reinstall the louver into the closed bracket first, then slide the
other end into the open bracket
5. Install safety barrier. Center the screen front over the glass
frame assembly, allowing the hanging brackets to fit inside the
air openings.
6. Align the notched tabs with the slots in the fireplace. Raise
slightly and push back to desired position.
7. Lower the screen front until the notched tabs are firmly in
position. Verify the depth accommodates finish material, and the
notched tabs position matches the louver notch position.
8. To remove safety screen: lift the screen up and out of slots.
OPEN END BRACKET
OPEN END BRACKET
LOUVER IN FIRST
LOUVER IN FIRST
POSITION ON OPEN
POSITION ON OPEN
END BRACKET
END BRACKET
LOUVER IN FIRST
LOUVER IN FIRST
POSITION ON CLOSED
POSITION ON CLOSED
END BRACKET
END BRACKET
CLOSED END BRACKET
CLOSED END BRACKET
FIGURE 4.7