3.6 Wall Enclosure Rough Opening
WARNING: Provide adequate clearance in front of the fireplace for
barrier removal, component access, gas line installation, service
access, etc.
NOTE: The construction of the fireplace wall enclosure must comply
with local building codes and all clearances as outlined in this manual.
NOTE: Cold air transfer area. The fireplace wall enclosure should be
constructed in a manner to prevent cold air from entering the room
and outside walls should be insulated.
•
Framing dimensions should allow for wall covering thickness
and fireplace facing materials. If using a hearth, adjust the rough
opening size as necessary to maintain minimum clearance
requirements.
•
If masonry (optional) is to be used, prepare the foundation
necessary for the full masonry load. A lintel must be used over
the top of the appliance to support the added weight of the
masonry construction above the fireplace.
Figure 3.3, Framing Dimensions
42”
(1067mm)
36
¼
”
(920 mm)
15
7⁄8
”
(403mm)*
½
” (13mm) TYPICAL
FINISH MATERIAL
*INCLUDES ½” (13mm) TYPICAL FINISH
MATERIAL WITH FLUSH MOUNT
SINGLE VERTICAL HEADER
BOARD IS REQUIRED TO
MAINTAIN CLEARANCES TO
COMBUSTIBLES