FAN KIT INSTALLATION
(continued)
1.
Remove the lower grill, if installed.
2.
OPTIONAL: For easier installation, the fans may be separated by unplugging the three-prong plug from the receptacle in the
right fan assembly.
3.
Slide the left fan (A) (without receptacle) through the lower grill opening (right side of the valve) and place over the (2) left
mounting studs (B) located towards the back of the fireplace.
3b. Slide the right fan (with receptacle) (C) through the lower grill opening (right side of the valve) and place over the (2) right side
mounting studs (D) located towards the back of the fireplace.
4.
Place nuts on mounting studs and tighten.
5.
If the fans were separated in step #2 above, plug fans together by inserting the three-prong male end on the short fan cord on
the left fan assembly into the receptacle in the right fan assembly.
6.
Remove the (2) screws securing the removable access panel (with electrical box & romex connector installed) from the side of
the fireplace.
7.
Insert 110V-120V wiring (with ground) through the romex connector and wire to the speed control / receptacle assembly
matching the black (hot), white (neutral) and green (ground) wires to the corresponding wire on the speed control / receptacle
assembly. NOTE: (3) wire nuts are included in the fireplace components packet.
8.
Secure the speed control / receptacle assembly (E) into the electrical box with the (2) screws provided.
9.
Replace the electrical access panel and secure with the (2) screws removed.
10. Place the temperature control switch (with magnet) on the bottom of the firebox.
11. Plug the fan cord (F) into the receptacle in the electrical box.
12. Turn on/off speed control counter-clockwise until it „clicks‟. This is the „OFF‟ position.
13. Turn the speed control „ON‟ by turning the knob clockwise past the „click‟ - this is the highest setting.
14. Replace lower grill, if removed in step #1 above.
The fan will not operate unless the speed control has been turned „ON‟. The fan will not turn „ON‟ until suffi-
cient heat is applied to the thermostatic control switch . The fan will turn „ON‟ and „OFF‟ automatically when
the fireplace heats and cools. Adjust fan to desired speed while it is running.
TEMPERATURE CONTROL SWITCH POSITION: Prior to adjusting the temperature control switch, unplug the 3
-prong plug on the fan cord from the receptacle. Adjust the position of the temperature control switch to a
warmer location under the firebox to turn the fan „ON‟ sooner or move it to a cooler location under the firebox
to turn the fan „ON‟ later. The fan will turn on when the sensor in the temperature control switch reaches 110
o
F
and will turn „OFF‟ when the sensors reach 90
o
F. After adjustment, plug the 3-prong plug on the fan cord into
the receptacle.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-Current edition.
Figure 11