THERMOSTAT, REMOTE CONTROL OR WALL SWITCH INSTALLATION
CAUTION: DO NOT CONNECT HIGH VOLTAGE (115V) TO ANY OF THESE SYSTEMS
If desired, a thermostat, wall switch, or remote control
assembly may be used to turn the fireplace „OFF‟ and
„ON‟. ONLY one of these may be installed. Follow in-
structions included with each assembly.
OPTIONAL: Disconnect the on/off rocker switch wires
from the top & bottom „TH‟ terminals on the back side of
the gas valve.
IMPORTANT: If the ON/OFF rocker switch wires are not
disconnected, the switch must be in the „OFF‟ position
for proper operation of these components.
NOTE: INSTALLATION OF A THERMOSTAT OR WALL
SWITCH SHOULD ONLY BE DONE BY A QUALIFIED
INSTALLER.
WALL SWITCH / THERMOSTAT USERS:
Run low-voltage (thermostat) wires from the terminals
on the gas valve to the desired location of the wall
switch or thermostat.
Attach the appropriate connector to each wall switch /
thermostat wire and connect to the top and bottom ter-
minals on the gas valve.
The ON/OFF rocker switch on the millivolt board must
be in the „OFF‟ position for proper operation of any of
these components.
If the rocker switch is „ON‟, the fireplace burner will oper-
ate until it is turned „OFF‟ by the rocker switch. A wall
switch, thermostat, or remote control will not turn the
fireplace „OFF‟ when it has been turned „ON‟ by the
rocker switch.
NOTE:
The fireplace must be turned „ON‟ and „OFF‟ by
the same method. For example: If the fireplace is turned
„ON‟ by the remote control, it must be turned „OFF‟ by
the remote control.
REMOTE CONTROL USERS:
Follow instructions included with the remote control.
IMPORTANT!
The insulated cover included with the remote control must be placed over the remote receiver box
to protect it from overheating. Failure to use this cover will result in voiding its warranty coverage.
Figure 14A
Figure 14B
Remote Control Wiring Diagram
Thermostat Wiring Diagram