TROUBLESHOOTING GUIDE (continued)
PROBLEM
CAUSE
SOLUTION
Burner won't light.
Pilot not lit.
Relight pilot.
Regulator valve not turned “on”.
Turn valve to "on".
Rocker switch not turned “on”.
Press bottom of switch.
Rocker switch wire not connected.
Check wiring diagram Figure 19 to ensure that all
wires are secure.
Generator wires loose at regulator terminals.
Reposition wire and tighten screws. See Figure
19 for wiring instructions.
Generator wire grounded out
Nuts securing millivolt board may need loosening
due to pinching of wires.
to remove pinched wire.
Generator is not producing enough
Replace generator.
millivolts to operate burner.
Wall switch, remote control or thermostat not
Connect properly or disconnect and use ON/OFF
connected properly or turned to wrong setting.
switch only. See Figures 14A - 14B.
Burner won't stay lit
Wall switch, thermostat wire too
Disconnect wires from valve. If burner stays lit,
thick or run more than 30 ft.
change location or use ON/OFF switch only.
Refractory panels not positioned against firebox.
Secure refractory panels with high-temp sealant,
especially around the intake duct.