UNIT SPECIFICATIONS -
Height (A):
25"
Front Width (B):
32"
Back width (C):
22”
Depth (D):
18 ¼”
Face to front of 7” intake:
7 ¾”
Face to center of 4” exhaust:
11 ¼”
Flue size: 4" exhaust, 7" intake
Flex Kits (4”x7”):
(pipe, cap, firestop)
- #745 Flexible TERMINATION KIT -
for
terminations 4' for less.
- #718 Flexible TERMINATION KIT -
for
terminations greater than 4' but less than 8'.
-#746 Flexible EXTENSION KIT -
used in
conjunction with #745 or #718. The extension
kit is expandable to 6'.
IMPORTANT:
THIS FIREPLACE IS APPROVED FOR USE WITH ONE OF THE FOLLOWING DIRECT VENT SYSTEMS:
Rigid Pipe (4”x6⅝”):
(vertical applications only)
-
#923-C adapter (Kozy Heat part) is required to
adapt the flue collar to the following systems.
● Simpson Dura Vent
● Selkirk
● AmeriVent
● Security
● EXCEL Direct
For visual inspection of proper vent connection; upon completion of installing the direct vent kit, remove the nuts and the baffle inside
the unit to expose the lower end of the flue gas exit. Re-install baffle upon inspection and secure with nuts - DO NOT OVER
TIGHTEN THE NUTS!
IMPORTANT: NON-COMBUSTIBLE FACING MATERIAL MAY BE APPLIED OVER THE FACE. TO PREVENT THE FACING MATERIAL FROM
CRACKING AND FALLING OFF DUE TO EXPANSION OF THE FACE WHEN HEATED, DO NOT ATTACH FACING MATERIAL DIRECTLY TO
THE FACE OF THE UNIT.
CLEARANCES
Minimum clearance to combustibles:
From unit sides & back:
0"
From unit top stand-off:
0"
To flooring:
0"
From flue vent:
1"
From unit glazing to adjacent sidewall:
8"
From heat outlet to mantel: See chart below -
GAS CONVERSIONS
This fireplace is manufactured for use with Natural Gas. An LP Gas conversion kit is included with this fireplace. Follow instructions
included with the conversion kit.
Natural Gas Conversion Kit -
used to convert an LP millivolt board to natural gas. Part: #OCK-S38
LP Gas Conversion Kit
- used to convert a Natural Gas millivolt board to LP Gas. Part: #OCK-S53
(included)
The conversion shall be carried out in accordance with the requirements of the provincial authorities having
jurisdiction and in
accordance with the requirements of the ANSI Z223.1 installation code.
MANTEL PROJECTION CHART