3
4.
Usage
①
Connect the discharge port side of the grease checker body directly to the bearing or to a pipe,
and connect the supply port side to the distribution valve outlet side pipe. (Figure 1)
※
At this time, be careful not to let dust get inside the grease checker or piping.
②
When the grease sent by pressure from the pump is sent to the grease checker through the
distribution valve, the indicator attached to the grease checker strokes up to confirm the
grease can be made sure to being sent. (Figure 2)
③
After the indicator attached to the grease checker is activated, manually push down the
push-in button to reset it when checking the equipment. (Figure. 3)
※
Pushing down the push-in button to the end, the built-in check valve is pushed down to
reduce the reverse flow of grease in the indicator stroke part, and releasing the internal
pressure to the bearing side, to prevent the indicator returns by back pressure.
④
The cracking pressure of the built-in check valve in grease checker can be adjusted. Looking
at the adjustment nut from the discharge side of the main unit, turning it to the right increases
the cracking pressure, and turning it counter-clockwise decreases the cracking pressure.
(Figure. 5)
⑤
It is also possible to supply grease with a manual grease gun or an electric grease gun from
the grease nipple mounted to the grease checker. (Figure. 4)
※
When using a manual or electric grease gun, pay attention to the discharge pressure and
do not exceed the grease checker operating pressure of Max.3MPa.
※
Figures are KGC-01
Figure. 1
Figure. 2
Figure. 3
Figure. 4
Figure. 5