21/27
F i l t e r C o n t r o l F S - 2 1
FS-21.doc | Status 2015 - 02 - 09
13
Application and Configuration Examples
13.1
Connection of Two FS-21 in Interconnected Operation
Connective operation is possible also between FS-21 and FS-201.
13.2
Connection of Several FS-21 in Interconnected Operation
13
K8
E5
E5
FS1 locks FS2
FS2 locks FS1
22 23 28
22 23 28
FS-21
FS-21
22 23 28
N PE
9
22 23 28
N
PE
K1
K2
K3
K1 ... K3: e. g. Finder Relay 55.3 4
9
22 23 28
N PE
FS-21
FS-21
FS-21