Electrical
Control Function
98
Electrical Control System
25
Indoor room temp. of 1# indoor unit
If the temp. is lower than -9 degree, the digital display tube will
show “9”.If the temp. is higher than 70 degree, the digital
display tube will show “70”. If the capacity demand is 0, , the
digital display tube will show “0. If the indoor unit is not
connected, the digital display tube will show: “
――
”
26
Indoor room temp. of 2# indoor unit
If the temp. is lower than 0 degree, the digital display tube will
show “0”.If the temp. is higher than 70 degree, the digital
display tube will show “70”. If the capacity demand is 0, , the
digital display tube will show “0. If the indoor unit is not
connected, the digital display tube will show: “
――
”
27
Average of Indoor room temp.
If the temp. is lower than 0 degree, the digital display tube will
show “0”.If the temp. is higher than 70 degree, the digital
display tube will show “70”.
28
Shutdown reason
Refer to Appendix
29
T2B of 1# indoor unit
If the temp. is lower than -9 degree, the digital display tube will
show “9”.If the temp. is higher than 70 degree, the digital
display tube will show “70”. If the capacity demand is 0, , the
digital display tube will show “0. If the indoor unit is not
connected, the digital display tube will show: “
――
”
30
T2B of 2# indoor unit
If the temp. is lower than 0 degree, the digital display tube will
show “0”.If the temp. is higher than 70 degree, the digital
display tube will show “70”. If the capacity demand is 0, , the
digital display tube will show “0. If the indoor unit is not
connected, the digital display tube will show: “
――
”
Appendix
Shutdown Reason
Code
Frequency limit caused by current
1
Frequency limit caused by T2.in cooling
2
Frequency limit caused by T2.in heating
3
Reach to the setting temperature
4
Frequency limit caused by T4.
5
Defrosting
6
Mode switching
7
High discharge temperature protection
9
High evaporator coil temp.T2 protection
10
Evaporator low temperature T2 protection
11
Condenser high temperature T3 protection
12
Low indoor room temperature protection in drying mode
13
Too low ambient temperature protection
14
Refrigerant leakage detection
15
Communication malfunction between indoor and outdoor units
16
Communication error between outdoor main chip and compressor driven chip IR341
17
AC voltage protection
18
Top temperature protection of compressor
19
Outdoor EE Malfunction
20
Fan speed has been out of control
21
Open or short circuit of temperature sensor
22
Overcurrent protection
23
IMP overcurrent protection
24
Compressor lack of phase
25
Compressor has been out of control
26
Low pressure protection of 311
27
Fan current protection
28
Fan lack of phase
29
Fan zero speed protection
30
PFC module protection
31
High pressure protection of 311
32
Zero speed malfunction
33
PWM malfunction
34
MCE malfunction
35
Compressor overcurrent protection
36
Compressor EE malfunction
37
Compressor start-up malfunction
38
311 fan speed has been out of control
39
Low pressure protection
40
High pressure protection
41
PFC module malfunction
42
Summary of Contents for KV24 ODU-ARF21C
Page 1: ......
Page 6: ...Nomenclature 4 General Information 3 Nomenclature 3 1 Indoor Outdoor Unit...
Page 11: ...Features Indoor Units 9 Alarm lamp Long distance on off controller...
Page 13: ...Service Space Indoor Units 11 3 Service Space 1000mm 1000mm 1000mm 1000m m...
Page 19: ...Field Wiring Indoor Units 17 9 Field Wiring 24K 36K...
Page 20: ...Field Wiring 18 Indoor Units 48K 60K...
Page 34: ...Field Wiring 32 Indoor Units 10 Field Wiring 24K 36K...
Page 35: ...Field Wiring Indoor Units 33 48K 60K...
Page 39: ...Service Space Indoor Units 37 3 Service Space...
Page 44: ...Ceiling Floor Type 42 Ceiling Floor Type 9 Field Wiring 24K 36K...
Page 45: ...Ceiling Floor Type Ceiling Floor Type 43 48K 60K...
Page 49: ...Service Space Floor standing Type 47 3 Service Space...
Page 50: ...Wiring Diagrams 48 Floor standing Type 4 Wiring Diagrams KV36FM ARF21C KV60FM ARF21C...
Page 55: ...Field Wiring Floor standing Type 53 9 Field Wiring 36K...
Page 56: ...Field Wiring 54 Floor standing Type 60K...
Page 59: ...Dimensions Outdoor Units 57 Model KBtu h Unit mm W D H W1 A B 48 60 952 415 1333 1045 634 404...
Page 62: ...Wiring Diagrams 60 Outdoor Units 4 Wiring Diagrams KV24ODU ARF21C KV36ODU ARF21C...
Page 63: ...Wiring Diagrams Outdoor Units 61 KV48ODU ARF21C KV60ODU CRF21C...
Page 103: ...Troubleshooting Electrical Control System 101 2 1 5 Display board of floor standing...
Page 113: ...Troubleshooting Electrical Control System 111 2 4 4 2 E1 malfunction For 485 communication E1...
Page 114: ...Troubleshooting 112 Electrical Control System 2 4 4 3 J4 malfunction J4...
Page 116: ...Troubleshooting 114 Electrical Control System 2 4 4 5 P6 malfunction P6...
Page 117: ...Troubleshooting Electrical Control System 115 2 4 4 6 J5 malfunction J5...
Page 119: ...Troubleshooting Electrical Control System 117 2 4 4 8 F0 malfunction F0...
Page 123: ...Troubleshooting Electrical Control System 121 2 4 4 12 J0 malfunction J0...