► Motion sensor with saved ambient brightness value:
To automatically program the ambient brightness, set
the sliding switch
6
to the AUTO position. The time
setting
8
may not be in the “test” position!
Set the adjustment screw
7.1
to the position
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
for at
least 1 second, thus activating the automatic brightness
detection.
As soon as the ambient brightness corresponds to the
brightness that should be saved, switch the adjustment
screw
7.1
from the position
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
directly to the
position
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
. The LED
10
in the sensor area begins to
blink for 10 seconds.
The ambient brightness is saved. Consumers and the LED
10
are then switched on for 5 seconds and then completely
switched off. The programming procedure is finished.
Repeat the programming procedure above, if another ambi-
ent brightness is to be saved.
Repeat the programming procedure after a loss of power.
If the motion sensor is to use the programmed brightness
value as a reference value for the twilight threshold after the
completion of the programming procedure, reset the adjust-
ment screw to position
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
.
Set the set screw to
position “
”
Set to position
for > 1 second
and back to position “
”
7.1
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5
1min.
20sek.
5sek.
Test
5min.
15min.
30min.
Zeit
Meter
300
100
30
5
300
100
30
5
300
100
30
5